Experimental analysis of fresh concrete under dynamic loading

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Five Parameter Viscoelastic Model Under Dynamic Loading

The purpose of this paper is to analysis the viscoelastic models under dynamic loading. A five-parameter model is chosen for study exhibits elastic, viscous, and retarded elastic response to shearing stress. The viscoelastic specimen is chosen which closely approximates the actual behavior of a polymer. The module of elasticity and viscosity coefficients are assumed to be space dependent i.e. f...

متن کامل

Experimental Study on Performance of Fiber Concrete-filled Tube Columns under Axial Loading

There have been great developments in the area of civil engineering in the recent few decades and among these, construction and material innovation are quite prominent. Steel-concrete composite construction has emerged as one of the fastest methods of construction. Even though considerable research efforts on conventional reinforced concrete columns have been executed prior to now, concrete fil...

متن کامل

Experimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading

To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356 a...

متن کامل

Experimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading

To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an &#10experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356...

متن کامل

Dynamic Analysis of Multihazard-Resistant Bridge Piers Having Concrete-Filled Steel Tube under Blast Loading

Research was conducted to analytically investigate the blast-response and behavior of multihazard-resistant bridge piers having circular-shaped, concrete-filled steel tube (CFST) columns. Two different analysis methods, namely a single-degree-of-freedom (SDOF) dynamic analysis and a fiber-based dynamic analysis, were used for this purpose and calibrated with the maximum residual deformations ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal de Physique IV (Proceedings)

سال: 2003

ISSN: 1155-4339

DOI: 10.1051/jp4:20020734