Experimental and Numerical Investigation on Seismic Performance of a Hybrid RC Frame System with Stiffened Masonry Wall
نویسندگان
چکیده
منابع مشابه
Investigation and Analysis of Empirical Field Seismic Damage to Bottom Frame Seismic Wall Masonry Structure
To understand the seismic damage characteristics of bottom frame-wall buildings and to study their seismic performance, the seismic damage outcomes of bottom frame-wall structures in Du jiang weir by the Wen chuan earthquake on May 12,2008, China were field observed and studied. The assesment of the seismic damage to the bottom frame-wall masonry in Du jiang weir urban showed that the damage t...
متن کاملEmpirical Seismic Vulnerability and Damage of Bottom Frame Seismic Wall Masonry Structure: A Case Study in Dujiangyan (China) Region
In order to understand the seismic performance and mechanism of bottom frame seismic wall masonry structure (BFSWMS) and its vulnerability in empirical seismic damage, based on the statistical and numerical analysis of the field seismic damage observation data of 2178 Dujiangyan structures in the Wenchuan great earthquake urban of China on May 12, 2008, a non-linear function model between the s...
متن کاملExperimental Investigation on Seismic Behavior of Steel Truss-RC Column Hybrid Structure with Steel Diagonal Braces
This paper aims to provide an experimental support on seismic performance evaluation of the steel braced truss-RC (reinforced concrete) column hybrid structure, which could be applied as the air-cooled supporting structural system in large-capacity thermal power plants located in strong earthquake prone regions. A series of pseudo-dynamic tests (PDTs) and quasi-static tests (QSTs) were performe...
متن کاملInvestigation of the Effects of Link Beam Length on the RC Frame Retrofitted with the Linked Column Frame System
This study investigates the effect of different link beam lengths in the Reinforced Concrete (RC) frame retrofitted with the Linked Column Frame (LCF) system. It also investigates the ratio of the link beam length (e) to the span length of the RC frame (L) from 0 to 1.5 for the 9 models of the RC frame retrofitted by the LCF system has been investigated. In addition, it studies the formation of...
متن کاملEvaluation of the Effect of Connection between RC Shear Wall and Steel Moment Frame on Seismic Performance and Reduction Factor in Dual Systems
Dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. These walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. In this research intermediate dual system of steel moment frame was chosen with int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Advanced Concrete Technology
سال: 2018
ISSN: 1346-8014,1347-3913
DOI: 10.3151/jact.16.600