Experimental Investigation for Non and Partially Composite Cold-Formed Steel Floor Beams

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation on Cold-formed Steel Wall Plate System

A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped Cchannel. The lipp...

متن کامل

Experimental Investigation on Cold-Formed Steel Foamed Concrete Composite Wall under Compression

A series of tests on cold-formed steel foamed concrete (CSFC) composite walls subjected to axial load were proposed. The primary purpose of the experiments was to study the mechanical behavior and identify the failure modes of CSFC composite walls. Two main factors were considered in this study: 1) specimen with pouring foamed concrete or without and 2) different foamed concrete density ranks (...

متن کامل

Local Buckling Tests on Cold-Formed Steel Beams

C and Z sections are two of the most common cold-formed steel shapes in use today. Accurate prediction of the bending performance of these sections is important for reliable and efficient cold-formed steel structures. Recent analytical work has highlighted discontinuities and inconsistencies in the American Iron and Steel Institute ~AISI! and Canadian Standards Association ~S136! design provisi...

متن کامل

Distortional Buckling Tests on Cold-Formed Steel Beams

Failure in cold-formed steel beams is generally initiated by one of three instabilities: local, distortional, or lateral-torsional buckling. For cold-formed steel joists, purlins, or girts, when the compression flange is not restrained by attachment to sheathing or paneling, distortional buckling may be the predominant failure mode. Experimental results on cold-formed steel beams with unrestrai...

متن کامل

On Cold-Formed Steel Construction

Powder-actuated (also referred to as low velocity or powder-driven) fasteners are commonly used to attach cold-formed steel framing members, usually a track, to a concrete or structural steel support. Although commonly used, their behavior is less well understood than other fasteners such as screws, bolts and welds. The AISI Cold-Formed Steel Design Manual does not explicitly address powder act...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Civil Engineering Journal

سال: 2019

ISSN: 2476-3055

DOI: 10.28991/cej-2019-03091341