To study mechanical behaviors of shear walls built with precast two-way hollow slabs, two shear walls with different details of hollow slabs were quasi-statically tested under low cyclic loading. The failure mode was analyzed, which vertical macro-cracks appeared on walls due to the details of hollow slabs. Brittle shear failure can be avoided in terms of the failure behaviors evolved from inte...
متن کاملExperimental Study on Flexural Behavior of Precast Concrete Shear Walls with Vertical Joint
متن کامل
Seismic Displacement Demands for Hybrid Precast Concrete Shear Walls
This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analy...
متن کاملExperimental Study on Shear Performance of Innovated Precast Shear Walls with Different Yield Strength Grades of Reinforcements
Result and Conclusion: The results show that strength of horizontal bars has a little influence on the hysteretic behavior and the deformation ability. While the decrease of the strength of horizontal bars can increase the yield displacement and the peak displacement of the hollow slab shear walls. The hollow slab shear wall structure has good deformation capacity, and the brittle shear failure...
متن کاملExperimental Study on New-typed Prefabricated Shear Walls with Vertical Joint Under Different Shear Span Ratio
The results show that the shear span ratio has significant effect on the mechanical behavior of the new-typed prefabricated shear walls, and the new-typed prefabricated shear walls have good ductility, all the ductility factors are greater than 4.0. The study also proves that the construction of the vertical joint is reasonable and its connection property is reliable. The vertical joint which c...