Experimental study on two-phase flow pressure drop in small diameter bends
نویسندگان
چکیده
منابع مشابه
Two Phase Flow Pressure Drop Calculation Using Homogeneous Equilibrium Model
Although two-phase flow is frequently encountered in various location of the process plants, there is no a general accepted and verified two-phase flow model that may be used to size lines for such conditions. An obvious example is condensate water return lines. The API method that used in this study is based on the homogeneous equilibrium flow assumption, that is, equal velocity and equal temp...
متن کاملNumerical Study of Single Phase/Two-Phase Models for Nanofluid Forced Convection and Pressure Drop in a Turbulence Pipe Flow
In this paper, the problem of turbulent forced convection flow of water- alumina nanofluid in a uniformly heated pipe has been thoroughly investigated. In numerical study, single and two-phase models have been used. In single-phase modeling of nanofluid, thermal and flow properties of nanofluid have been considered to be dependent on temperature and volume fraction. Effects of volume fraction a...
متن کاملTwo Phase Heat Transfer Characteristics in a Vertical Small Diameter Tube at Sub Atmospheric Pressure
Two-phase heat transfer is experimentally examined through vertical small diameter tubes, D =1.45 and 2.8 mm using water under a pressure of 50 to 81 kPa and a natural circulation condition. The pool boiling correlation by Stephan-Abdelsalam and the thermosyphon boiling correlation by Imura, et al. predict the measured experimental data in the 2.8 mm tube with an error of -30%. A large heat tra...
متن کاملFlow visualization and pressure drop for refrigerant phase change and air-water flow in small hydraulic diameter geometries
A comprehensive study of two-phase flow mechanisms and pressure drop in horizontal small hydraulic diameter tubes was conducted. Co-current flow of air-water mixtures in four round tubes and one rectangular tube with hydraulic diameters ranging from 5.5 mm to 1.3 mm were investigated. Bubble, dispersed, elongated bubble, slug, stratified, wavy, annular-wavy, and annular flow patterns were obser...
متن کاملEffect of diameter on two-phase pressure drop in narrow tubes
0894-1777/$ see front matter 2010 Elsevier Inc. A doi:10.1016/j.expthermflusci.2010.12.007 ⇑ Corresponding author. Tel.: +91 44 2257 4154. E-mail address: [email protected] (A.R. Balakrishna The effect of tube diameter on two-phase frictional pressure drop was investigated in circular tubes with inner diameters of 0.6, 1.2, 1.7, 2.6 and 3.4 mm using air and water. The gas and liquid superficial...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Perspectives in Science
سال: 2016
ISSN: 2213-0209
DOI: 10.1016/j.pisc.2016.06.038