Experimental validation of radiometric sensitivity in correlation radiometers

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental validation of radiometric sensitivity in correlation radiometers - Electronics Letters

Assuming a symmetric transmit filter for which the receive filter is to be optimised, we expect the symmetric receive fdter coefficients (eqn. 12) to be practically the same as those for the nonsymmetric filters (eqn. 5). This is verified by a set of examples with different receive filter lengths NR and transmit filter excess bandwidth values a. An AWGN channel with SNR = 8dB (i.e. no linear di...

متن کامل

Spectroscopy with Multichannel Correlation Radiometers

Correlation radiometers make true differential measurements in power with high accuracy and small systematic errors. This receiver architecture has been used in radio astronomy for measurements of continuum radiation for over 50 years; this article examines spectroscopy over broad bandwidths using correlation techniques. After general discussions of correlation and the choice of hybrid phase ex...

متن کامل

Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals

The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers' outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers ...

متن کامل

Experimental validation of 20nm sensitivity of Singular Beam Microscopy

Quickly developing nanotechnology drives the industrial need for fast but sensitive nano-scale feature detection and evaluation. In this work we bypass the diffraction limit for achieving nanoscale sensitivity by introducing optical singularities into the illuminating beam for a modified laser scanning microscopic architecture. A good correspondence was obtained between laboratory experiments a...

متن کامل

Corrections To "Radiometric Sensitivity Computation In Aperture Synthesis Interferometric Radiometry"

(a) (b) Fig. 3. (a) Observation of " 00 change of ice slab on duraluminum mold at 13. the other hand, quick freezing may produce a specific distribution of salt concentration in ice volume. However, the main result of the measurements, as it follows from Figs. 2 and 3, is the hysteresis of " 00 in the case of slow-cycle temperature change for many days. Our other experiments with different temp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electronics Letters

سال: 1998

ISSN: 0013-5194

DOI: 10.1049/el:19981662