Factors affecting gentamicin assay
نویسندگان
چکیده
منابع مشابه
Factors affecting the assay of hyaluronidase.
A number of different types of assay methods have been developed for the determination of hyaluronidase activity in vitro. These include the mucin clot test (1, 2), the viscosimetric assay (3-12), the turbidimetric assay (7, 13-17), and the reductimetric assay (18). Of these, the turbidimetric and viscosimetric assays have been used most widely. In the work reported here a study has been made o...
متن کاملA spectrophotometric assay for gentamicin.
A rapid and accurate spectrophotometric assay has been developed for the determination of blood werum levels of gentamicin and related antibiotics. The assay uses a purified enzyme from Escherichia coli JR88/C600 that acetylates gentamicin with the production of coenzyme A, linked to a chemical reaction with a sulfhydryl reagent to produce stoichiometric amounts of a sensitive chromophore, moni...
متن کاملFactors affecting assay of myoglobin by complement fixation or immunodiffusion.
Quantitative micro-scale complement-fixation and semi-quantitative gel immunodiffusion assays for myoglobin have been evaluated experimentally and used to measure myoglobin in the sera of more than 1500 patients. We report certain problems, observations, and methodological improvements. Serum caused enhancement of precipitin lines in the immunodiffusion assay. In the complement-fixation assay,...
متن کاملFactors affecting a cyanogen bromide-based assay of thiamin.
We analyzed extensively a modified thiochrome method for thiamin analysis. Acid phosphatase (EC 3.1.3.2) from potato was superior to either alpha-amylase or acid phosphatase from wheat germ as a dephosphorylating agent. Timing of cyanogen bromide exposure was important, but the assay had good precision and accuracy. The standard curve was linear from 10 to 3000 nmol/L. The within-run and betwee...
متن کاملAssay of gentamicin in cerebrospinal fluid.
A comparison of standard curves obtained from a conventional plate diffusion assay method revealed significant differences when gentamicin standards were made up in different media. Standards made up in distilled water resulted in a curve which differed from that of standards made up in pooled human cerebrospinal fluid by a factor of up to 4. When the assay medium was supplemented with 0-5% sod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Antimicrobial Agents and Chemotherapy
سال: 1980
ISSN: 0066-4804,1098-6596
DOI: 10.1128/aac.17.6.918