Failure analysis of air cooled condenser gearbox

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anti-Freezing Mechanism Analysis of a Finned Flat Tube in an Air-Cooled Condenser

In cold winter weather, the air-cooled condensers (ACCs) face serious freezing risks, especially with part load of the power generating unit. Therefore, it is of benefit to investigate the heat transfer process between the turbine exhaust steam and cooling air, by which the freezing mechanism of the finned tube bundles can be revealed. In this work, the flow and heat transfer models of the cool...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preve...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper,&#10 the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby pre...

متن کامل

Control of Air-Cooled Chiller Condenser Fans using Clustering Neural Networks

This study investigates task -blind and task -specific training methods to determine appropriate radial basis function based neural network architectures. These neural nets identify system behavior of air-cooled chiller condensers by grouping dominant features (clustering) of measured chiller performance data. Task specific clustering proved superior but more computationally demanding than task...

متن کامل

Analysis of Zeotropic Mixture in a Geothermal Organic Rankine Cycle Power Plant with an Air-cooled Condenser

The purpose of this research is to investigate a zeotropic working fluid mixture in terms of its performance in an organic Rankine cycle (ORC) and the heat transfer characteristics in an air-cooled condenser (ACC). The motivation of this study is that it is well known that the use of a mixture improves the efficiency of an ORC system. However, the behaviour of the mixture in the condensers is n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Case Studies in Engineering Failure Analysis

سال: 2014

ISSN: 2213-2902

DOI: 10.1016/j.csefa.2014.08.003