False fMRI activation after motion correction
نویسندگان
چکیده
منابع مشابه
Comparison of fMRI motion correction software tools.
Motion correction of fMRI data is a widely used step prior to data analysis. In this study, a comparison of the motion correction tools provided by several leading fMRI analysis software packages was performed, including AFNI, AIR, BrainVoyager, FSL, and SPM2. Comparisons were performed using data from typical human studies as well as phantom data. The identical reconstruction, preprocessing, a...
متن کاملProspective multiaxial motion correction for fMRI.
Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagittal, axial, and coronal planes into the fMRI pulse sequence, rotation and tran...
متن کاملTheoretical Analysis of the Effect of fMRI Brain Activation on Motion Correction
The presence of BOLD contrast in M R I studies has been shown to interfere with least squares motion correction algorithms. We derive a theoretical expression for the error that activation contributes to least squares motion correction. These estimates match errors generated by motion correction experiments done on a simulated fMRl dataset. The analysis is not specific to activation related err...
متن کاملSlice-by-slice motion correction in spinal cord fMRI: SliceCorr
Introduction Subject motion in functional magnetic resonance imaging (fMRI) is highly problematic for the detection of responses showing small effect size and/or spatially extent. To mitigate this problem, various methods have been proposed to correct this type of motion a posteriori. These methods correct each volume using a 3D rigid-body matrix having six parameters for translation and rotati...
متن کاملEEG-assisted retrospective motion correction for fMRI: E-REMCOR
We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are utilized for slice-specific motion correction of unprocessed fMRI data. Performance of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Human Brain Mapping
سال: 2017
ISSN: 1065-9471
DOI: 10.1002/hbm.23677