FANM: A software for focus and aberrations of nuclear microprobe
نویسندگان
چکیده
Focus and Aberrations of Nuclear Microprobe (FANM) is a new beam optics package to achieve fast accurate design nuclear microprobe. FANM achieves balance between speed focusing accuracy high order aberrations. A combined method proposed in conditions using matrix calculate aberration coefficients numerical ray tracing method. has two optional optimization algorithms (derivative-free particle swarm optimization), offering powerful choice for multi-variable optimization. Numeric variables are stored as 64-bit (8-byte) double-precision floating-point values reduce calculation errors. Results obtained with compared six existing computational tools (PRAM, TRANSPORT-PSI, TRANSPORT-PBO, WinTRAX, GEANT4-nanobeam Zgoubi). The reasons discrepancies the different packages discussed. Calculated currents magnetic quadrupole lenses experimental microprobe National University Singapore.
منابع مشابه
a new algorithm and software of individual life insurance and annuity computation
چکیده ندارد.
15 صفحه اولthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولThe nuclear microprobe: a unique instrument
There are several features characterising high-energy ion interactions with matter which enables techniques which utilise the high-energy ion beam to have unique or advantageous characteristics. (i) The lack of primary particle bremsstrahlung enables Particle Induced X-ray Emission (PIXE) to be carried out with very little X-ray background, and therefore correspondingly high analytical sensitiv...
متن کاملNew Generation Nuclear Microprobe Systems
Over the past 20 years, the minimum probe size for nuclear microscopy has stayed around 1 micrometre. No breakthroughs in nuclear microprobe design have been forthcoming to produce dramatic improvements in spatial resolution. The difficulties of breaking the constraints that are preventing reduction of the probe size have been well recognised in the past. Over the past 5 years it has become cle...
متن کاملpassivity in waiting for godot and endgame: a psychoanalytic reading
this study intends to investigate samuel beckett’s waiting for godot and endgame under the lacanian psychoanalysis. it begins by explaining the most important concepts of lacanian psychoanalysis. the beckettian characters are studied regarding their state of unconscious, and not the state of consciousness as is common in most beckett studies. according to lacan, language plays the sole role in ...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ultramicroscopy
سال: 2021
ISSN: ['0304-3991', '1879-2723']
DOI: https://doi.org/10.1016/j.ultramic.2020.113163