Fast-kz three-dimensional tailored radiofrequency pulse for reducedB1 inhomogeneity
نویسندگان
چکیده
منابع مشابه
Small-tip Fast Recovery (STFR) imaging Using Spectrally Tailored Pulse
Introduction: Small tip fast recovery (STFR) imaging has been proposed recently as a potential alternative to balanced steady state free precession (bSSFP) [1, 2]. STFR relies on a tailored “tip-up” RF pulse (Fig. 1(a)) to achieve comparable signal level and image contrast as bSSFP, but with reduced banding artifacts. Previous STFR implementations used 2D or 3D pulses spatially tailored to the ...
متن کاملFast three-dimensional Texture Synthesis
Three-dimensional (3D) textures are popular for texturing solid objects. They usually achieve superior results over conventional two-dimensional (2D) texture mapping techniques. However, whereas 2D textures can be obtained using for example a photograph, capturing or generating solid textures is not straightforward. Procedural techniques can replicate some types of materials, but are usually di...
متن کاملTailored RF Pulse Design for 7T MRI
The primary concern of this thesis is in the design of RadioFrequency (RF) Pulses to be used for Ultra-High Field Magnetic Resonance Imaging. A movement towards higher magnetic field strength has noted advantages. In particular, increased Signal to Noise Ratio (SNR) with increasing field strength. However higher field strength also poses difficult problems, as a result of increasing inhomogenei...
متن کاملFast three-dimensional terahertz computed tomography using real-time line projection of intense terahertz pulse.
We demonstrated fast three-dimensional transmission terahertz computed tomography by using real-time line projection of intense terahertz beam generated by optical rectification in lithium niobate crystal. After emphasizing the advantage of intense terahertz pulse generation for two-dimensional spatio-temporal terahertz imaging, peak-to-peak amplitudes of pulsed terahertz electric field have be...
متن کاملSingle shot three‐dimensional pulse sequence for hyperpolarized 13C MRI
PURPOSE Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2006
ISSN: 0740-3194,1522-2594
DOI: 10.1002/mrm.20840