Fast Projection Matching for X-ray Tomography
نویسندگان
چکیده
منابع مشابه
Fast and flexible X-ray tomography using the ASTRA toolbox.
Object reconstruction from a series of projection images, such as in computed tomography (CT), is a popular tool in many different application fields. Existing commercial software typically provides sufficiently accurate and convenient-to-use reconstruction tools to the end-user. However, in applications where a non-standard acquisition protocol is used, or where advanced reconstruction methods...
متن کاملFast volume scanning approaches by X-ray-computed tomography
X-ray-computed tomography (CT) successfully underwent a transition from slice-by-slice imaging to volume imaging in the decade after 1990 due to the introduction of spiral scan modes. Later, the transition from single-slice to multislice scanning followed. With the advent of new detector technologies we are now looking forward to circular and spiral scanning using area detectors and the respect...
متن کاملFast Least Square Matching
Least square matching (LSM) is one of the most accurate image matching methods in photogrammetry and remote sensing. The main disadvantage of the LSM is its high computational complexity due to large size of observation equations. To address this problem, in this paper a novel method, called fast least square matching (FLSM) is being presented. The main idea of the proposed FLSM is decreasing t...
متن کاملEmpirical correlation for porosity deduction from X-ray computed tomography (CT)
For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...
متن کاملSoft-x-ray projection lithography
Soft-x-ray projection imaging is demonstrated by the use of 14-nm radiation from a laser plasma source and a single-surface multilayer-coated ellipsoidal condenser. Aberrations in the condenser and the Schwarzschild imaging objective are characterized and correlated with imaging performance. A new Schwarzschild housing, designed for improved alignment stability, is described.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2017
ISSN: 2045-2322
DOI: 10.1038/s41598-017-04020-0