Fatigue and fracture of a 316 stainless steel metal matrix composite reinforced with 25% titanium diboride

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatigue and fracture of a 316 stainless steel metal matrix composite reinforced with 25% titanium diboride

Fatigue and fracture mechanisms have been studied in a steel-based metal matrix composite (MMC), comprising a 316L austenitic matrix reinforced with 25 wt% particulate titanium diboride (TiB2). The fracture toughness was determined in the as-HIPped condition as being slightly below 30 MPa√m. Fatigue crack growth rates have been determined, and corrected for the effects of crack closure. The fra...

متن کامل

The Unified Creep-Fatigue Equation for Stainless Steel 316

Background—The creep-fatigue properties of stainless steel 316 are of interest because of the wide use of this material in demanding service environments, such as the nuclear industry. Need—A number of models exist to describe creep-fatigue behaviours, but they are limited by the need to obtain specialized coefficients from a large number of experiments, which are time-consuming and expensive. ...

متن کامل

Comparative MRI compatibility of 316 L stainless steel alloy and nickel-titanium alloy stents.

The initial success of coronary stenting is leading to a proliferation in peripheral stenting. A significant portion of the stents used in a clinical setting are made of 316 low carbon stainless steel (SS). Other alloys that have been used for stent manufacture include tantalum, MP35N, and nickel-titanium (NiTi). The ferromagnetic properties of SS cause the production of artifacts in magnetic r...

متن کامل

Mechanical and Tribological Behavior of Aluminum Alloy LM13 Reinforced with Titanium Dioxide Metal Matrix Composites

In the present research work physical, mechanical and tribological behavior of Aluminum (Al) alloy LM13 reinforced with Nano-sized Titanium Dioxide (TiO2) particulates were fabricated, mechanical and tribological properties were investigated. The amount of nano TiO2 particulates in the composite was added from 0.5% to 2% in 0.5 weight percent (wt %) increments. The Al-LM13-TiO2 Metal Matrix Com...

متن کامل

Composite rebonding to stainless steel metal using different bonding agents.

The purpose of this study was to determine the in vitro bond strengths of composite rebonded to stainless steel crown metal (SS) using five different bonding agents after composite to SS bond failure had been produced. The adhesive systems were applied to the failed bonds following the manufacturers' instructions and, as a control, composite was bonded to SS without using a bonding agent. Each ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Fatigue

سال: 2013

ISSN: 0142-1123

DOI: 10.1016/j.ijfatigue.2012.09.016