Fatigue Life Evaluation under Service Loading by Frequency Domain Method
نویسندگان
چکیده
منابع مشابه
Inverse first-order reliability method for probabilistic fatigue life prediction of composite laminates under multiaxial loading
Inverse first-order reliability method for probabilistic fatigue life prediction of composite laminates under multiaxial loading Yibing Xiang and Yongming Liu* Department of Civil and Environmental Engineering Clarkson University Potsdam NY.13699, USA Abstract: Multiaxial fatigue reliability is a challenging problem despite extensive progress made during the past few decades. Anisotropic materi...
متن کاملImproved Method of Rolling Bearing Fatigue Life Prediction Under Edge Loading Conditions
More than half a century has passed since Lundberg and Palmgren (referred to as LP in the following) established a theory on the life of rolling bearings 1) 2), and problems with the theory such as its lack of capability of considering shear force (tangential force) on the surface caused by slip or the initial or residual stress due to fit have been pointed out, with correction to these problem...
متن کاملEffect of the Loading Spectrum and History Length on Fatigue Life Distribution under Random Loading
One major source of error commonly encountered in determining the fatigue life of a given element arises from the loads involved, which are usually of random nature. As a rule, resistance analyses, carried out by simulation or tests, are done by using a loading history accounting for the real loads involved that is repeated indefinitely until failure is encountered. The result is one of the man...
متن کاملFatigue Analysis for Structures under Stochastic Loading
Predicting the peak distribution of stochastic stress responses is critical for various fatigue analysis problems with stochastic uncertainties. In this paper, a method, based on the first-order reliability method (FORM), is proposed for estimating the peak distribution of stochastic response. The method linearizes the stochastic process at the associated most probable point. After linearizatio...
متن کاملBiodegradation of polyurethane under fatigue loading.
A method utilizing expansion of a diaphragm-type film specimen was developed to study in vitro biodegradation of poly(etherurethane urea) (PEUU) under conditions of dynamic loading (fatigue). A finite element model was used to describe the strain state, which ranged from uniaxial at the edges of the film to balanced biaxial tensile strain at the center. During testing, the film was exposed to a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Society of Materials Science, Japan
سال: 2008
ISSN: 1880-7488,0514-5163
DOI: 10.2472/jsms.57.1186