Fatigue Strength of Highly Crosslinked Polyethylene in Total Ankle Arthroplasty
نویسندگان
چکیده
منابع مشابه
Wear Reduction in Total Ankle Arthroplasty Using Highly Crosslinked UHMWPE
Introduction: Bearing couples within total ankle arthroplasty (TAA) typically utilize cobalt chromium alloys articulating on ultrahigh molecular weight polyethylene (UHMWPE). Articulation of these surfaces during in vivo loading can generate UHMWPE wear particles, which may then result in osteolysis and component loosening [1]. Osteolysis has been observed following TAA in 15-22% of patient pop...
متن کاملRetrieval Analysis of Sequentially Annealed Highly Crosslinked Polyethylene Used in Total Hip Arthroplasty
BACKGROUND First-generation annealed and second-generation sequentially annealed, highly crosslinked polyethylenes (HXLPEs) have documented reduced clinical wear rates in their first decade of clinical use compared with conventional gamma inert-sterilized polyethylene. However, for both types of annealed HXLPE formulations, little is known about their reasons for revision, their in vivo oxidati...
متن کاملOutcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty
Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Usi...
متن کاملIn vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases.
This is the first report of in vivo wear particles from four total hip arthroplasties using remelted highly crosslinked polyethylene. The number of particles was (1.51 ± 0.45) × 10(7) g(-1) (mean ± standard error); particle size (equivalent circle diameter), 0.72 ± 0.15 µm; and roundness, 1.45 ± 0.05. Remelted highly crosslinked polyethylene generates fewer, rounder, equivalently sized particle...
متن کاملWear of highly crosslinked polyethylene acetabular components
BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...