Fault Current Characteristics of the DFIG under Asymmetrical Fault Conditions
نویسندگان
چکیده
منابع مشابه
Fault Current Characteristics of the DFIG under Asymmetrical Fault Conditions
During non-severe fault conditions, crowbar protection is not activated and the rotor windings of a doubly-fed induction generator (DFIG) are excited by the AC/DC/AC converter. Meanwhile, under asymmetrical fault conditions, the electrical variables oscillate at twice the grid frequency in synchronous dq frame. In the engineering practice, notch filters are usually used to extract the positive ...
متن کاملStudy on Fault Current of DFIG during Slight Fault Condition
In order to ensure the safety of DFIG when severe fault happens, crowbar protection is adopted. But during slight fault condition, the crowbar protection will not trip, and the DFIG is still excited by AC-DCAC converter. In this condition, operation characteristics of the converter have large influence on the fault current characteristics of DFIG. By theoretical analysis and digital simulation,...
متن کاملDecoupled Feed Forward Voltage Oriented Controller for DFIG under Balanced and Unbalanced Fault Conditions
As Wind Power Penetration increases continuously in total Power Generation, the wind turbines are necessary to stay connected to grid even under grid disturbances. An enhanced control strategy for DFIG is proposed in the present paper to meet the latest grid codes set by grid operators. The Decoupled Current Controller implemented in Grid Voltage oriented reference frame is applied to Grid Side...
متن کاملFault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملInvestigating Direct Torque Control of Six-Phase Induction Machines Under Open Phase Fault Conditions
This paper presents analysis and evaluation of classical direct torque control(DTC), for controlling a symmetrical six phase induction motor (SPIM) under open phasefault conditions. The machine has two three-phase windings spatially shifted by 60 electricaldegrees. The strategy of the proposed method consists of choosing the switching modesaccording to the configuration of living phases in such...