Internal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform
In this paper, a novel method is presented for detection and classification of the faultyphase/region in the stator winding of synchronous generators on the basis of the resulting harmoniccomponents that appear in the terminal voltage waveforms. Analytical results obtained through DecisionTree (DT) show that the internal faults are not only detectable but also they can be classified andthe rela...
متن کاملdesign of a self tuning voltage regulator for synchronous generators
this paper presents a self-tuning pid (proportional and integral and derivative) controller for regulating terminal voltage synchronous generators. in order to modify the system reponse and to overcome the difficulties of self tuning controllers, a dual rate sampling control system was used. system results demonstrated usfulness of the proposed regulator. the designed controller is simple and c...
متن کاملMitigation of Voltage and Current Harmonics Using UPQC Base On Synchronous Reference Frame Method
1 PG Student, Dept of EE, Mata Raj Kaur Institute of Engineering & Technology, Saharanwas, Rewari, India 2 Associate Professor & HOD, Dept of EE, Mata Raj Kaur Institute of Engineering & Technology, Saharanwas, Rewari, India ---------------------------------------------------------------------***--------------------------------------------------------------------ABSTRACT: This paper presents a ...
متن کاملSeries Resonance Based Fault Current Limiter with Controlling The Point of Common Coupling Voltage
This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...
متن کاملScalable fault models for diagnosis of synchronous generators
In this paper, we experiment with a small working model (SWM), where we can inject faults and learn the intelligence about the system, then scale up this fault models to monitor the condition of an actual/complex system, without injecting faults in the actual system. We refer to this approach as scalable fault models. We check the effectiveness of our approach using 3 kVA and 5 kVA synchronous ...