Fault Detection and Localization in Active Distribution Networks Using Optimally Placed Phasor Measurements Units

نویسندگان

چکیده

This paper introduces an algorithm able to detect and localize the occurrence of a fault in Active Distribution Network, using measurements collected by Phasor Measurement Units (PMUs). First, basic that works under assumption all grid buses are equipped with PMU is designed. Then, formal observability conditions allow detection localization reduced number PMUs provided. Based on these conditions, extended perform correctly when not network monitored. Moreover, Optimal Positioning Algorithm, always based allows user customize resolution. The approach validated through simulations carried out benchmark active distribution network.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

fault location in power distribution networks using matching algorithm

چکیده رساله/پایان نامه : تاکنون روش‏های متعددی در ارتباط با مکان یابی خطا در شبکه انتقال ارائه شده است. استفاده مستقیم از این روش‏ها در شبکه توزیع به دلایلی همچون وجود انشعاب‏های متعدد، غیر یکنواختی فیدرها (خطوط کابلی، خطوط هوایی، سطح مقطع متفاوت انشعاب ها و تنه اصلی فیدر)، نامتعادلی (عدم جابجا شدگی خطوط، بارهای تک‏فاز و سه فاز)، ثابت نبودن بار و اندازه گیری مقادیر ولتاژ و جریان فقط در ابتدای...

Fault Location in Active Distribution Networks Using Improved Whale Optimization Algorithm

To realize the self-healing concept of smart grids, an accurate and reliable fault locator is a prerequisite. This paper presents a new fault location method for active power distribution networks which is based on measured voltage sag and use of whale optimization algorithm (WOA). The fault induced voltage sag depends on the fault location and resistance. Therefore, the fault location can be f...

متن کامل

Anomaly Detection Using Optimally-Placed Micro-PMU Sensors in Distribution Grids

As the distribution grid moves toward a tightlymonitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. In this paper, focusing on Micro-Phasor Measurement Unit (μPMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and...

متن کامل

Fast Initial State Assessment for State Estimator using Optimally Located Phasor Measurement Units

Complex power systems need better observability and visualization capabilities to handle critical situations effectively. Synchro-phasor measurements provide intra second visibility to power system dynamics and enable faster control actions. A Phasor Measurement Unit (PMU) measures the voltage and current phasors (angle and magnitude) at a bus in a power system. In the literature, many methods ...

متن کامل

Using of Clustering Techniques in Optimal Placement of Phasor Measurements Units

The phasor measurement unit (PMU) is considered to be one of the most important measuring devices in the future of power systems. The distinction comes from its unique ability to provide synchronized phasor measurements of voltages and currents from widely dispersed locations in an electric power grid. This paper proposes an algorithm based on the clustering techniques for solving the optimal P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Systems

سال: 2023

ISSN: ['0885-8950', '1558-0679']

DOI: https://doi.org/10.1109/tpwrs.2022.3165685