Fault Ride through Capability Augmentation of a DFIG-Based Wind Integrated VSC-HVDC System with Non-Superconducting Fault Current Limiter
نویسندگان
چکیده
منابع مشابه
Control Design Strategy to Enhance the Fault-Ride-Through Capability of VSC-HVDC Transmission System Interconnecting Offshore Wind Power Plant
Most of the wind power plants currently installed at North Sea are near to shore connected with the onshore grid through AC cable. AC transmission technology is proven and reliable, but there will be a need to switch from AC to DC transmission since large number of offshore power plants at longer distance to shore are expected to be installed by the end of 2020. Furthermore, to enhance the inte...
متن کاملCoordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaa...
متن کاملInvestigation on Fault-ride Through Methods for VSC-HVDC Connected Offshore Wind Farms
Recently, there has been a fast development and deployment of wind energy to meet the increasing electrical power demand and to limit the use of fossil fuels. More and more wind farms are planned far from shore because of good wind condition and less visual impact. This is so called offshore wind farm (OWF). In such a situation, high voltage direct current (HVDC) transmission is a favorable opt...
متن کاملSecond-order sliding mode control for DFIG-based wind turbines fault ride-through capability enhancement.
This paper deals with the fault ride-through capability assessment of a doubly fed induction generator-based wind turbine using a high-order sliding mode control. Indeed, it has been recently suggested that sliding mode control is a solution of choice to the fault ride-through problem. In this context, this paper proposes a second-order sliding mode as an improved solution that handle the class...
متن کاملA New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter
In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sustainability
سال: 2019
ISSN: 2071-1050
DOI: 10.3390/su11051232