In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملExperimental fault-tolerant control of a PMSM drive
The paper describes a study and an experimental verification of remedial strategies against failures occurring in the inverter power devices of a permanent-magnet synchronous motor drive. The basic idea of this design consists in incorporating a fourth inverter pole, with the same topology and capabilities of the other conventional three poles. This minimal redundant hardware, appropriately con...
متن کاملSingle Open-phase Fault Detection with Fault-Tolerant Control of an Inverter-fed Permanent Magnet Synchronous Machine
In this paper first a current predictive method for single open-phase fault detection in a three phase drive with a permanent magnet synchronous machine is presented. The proposed method is based on a predictive stator current calculation. For each sampling interval the difference between the actual stator current and its predicted value in a previous sampling interval is calculated. To identif...
متن کاملSimplified Minimum Copper Loss Remedial Control of a Five-Phase Fault-Tolerant Permanent-Magnet Vernier Machine under Short-Circuit Fault
Abstract: A fault-tolerant permanent-magnet vernier (FT-PMV) machine incorporates the merits of high fault-tolerant capability and high torque density. In this paper, a new remedial control is proposed for a five-phase FT-PMV machine with short-circuit fault of stator windings. Based on the principle of copper loss minimization, the aims of the proposed control strategy are to keep magnetic mot...
متن کاملResearch on a 20-Slot/22-Pole Five-Phase Fault-Tolerant PMSM Used for Four-Wheel-Drive Electric Vehicles
This paper presents a five-phase fault-tolerant permanent-magnet synchronous machine (PMSM) used for electric vehicles. In multiphase fault-tolerant PMSMs equipped with fractional-slot concentrated windings, excessive magneto-motive force (MMF) harmonics can lead to thermal demagnetization of the permanent magnets (PMs). In order to reduce the lower-order harmonics, the origins of the 2-pole ha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Industrial Electronics
سال: 2016
ISSN: 0278-0046,1557-9948
DOI: 10.1109/tie.2014.2386299