Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis
نویسندگان
چکیده
منابع مشابه
Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis
BACKGROUND Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. METHODS 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for "Transthoracic," "Foot to...
متن کاملMeasurement of nutritional status in simulated microgravity by bioelectrical impedance spectroscopy.
The potential of bioelectrical impedance spectroscopy (BIS) for assessing nutritional status in spaceflight was tested in two head-down-tilt bed-rest studies. BIS-predicted extracellular water (ECW), intracellular water (ICW), and total body water (TBW) measured using knee-elbow electrode placement were compared with deuterium and bromide dilution (DIL) volumes in healthy, 19- to 45-yr-old subj...
متن کاملVariability of k terms in bioelectrical impedance spectroscopy.
Ellis et al described the validation of bioelectrical impedance spectroscopy (BIS) for measurement of volumes of intracellular water (ICW) and extracellular water (ECW) in healthy children (1). When they compared BIS with the dual-energy X-ray absorptiometry (DXA) and total body potassium (TBK) model, new k terms for the BIS computer model in children were derived. Their study is an important c...
متن کاملEstimation of segmental muscle volume by bioelectrical impedance spectroscopy.
This study validated bioelectrical impedance spectroscopy (BIS) with Cole-Cole modeled measurements of calf and arm segmental water volume and volume changes during 72 h of simulated microgravity and caloric restriction by using magnetic resonance imaging (MRI) muscle volume as a criterion method. MRI and BIS measurements of calf and upper arm segments were made in 18 healthy men and women [age...
متن کاملExperimental verification of depolarization effects in bioelectrical impedance measurement.
The electrode polarization effects on bioelectrical impedance measurement at low-frequency cannot be ignored. In this paper, the bioelectrical data of mice livers are measured to specify the polarization effects on the bio-impedance measurement data. We firstly introduce the measurement system and methodology. Using the depolarization method, the corrected results are obtained. Besides, the spe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BioMed Research International
سال: 2015
ISSN: 2314-6133,2314-6141
DOI: 10.1155/2015/810797