Fiducial markers configuration optimization in image-guided surgery

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fiducial markers configuration optimization in image-guided surgery.

The rigid registration is a key step of Image Guided Surgery (IGS), and the point-pair method is the main way used for registration. However the configuration of fiducial points has a great influence on the registration accuracy at the target point. Now almost all the optimization method of fiducial points configuration relies on the empirical simulation-based Fitzpatrick's target registration ...

متن کامل

Minimal Inter-Fractional Fiducial Migration during Image-Guided Lung Stereotactic Body Radiotherapy Using SuperLock Nitinol Coil Fiducial Markers

OBJECTIVES Stereotactic body radiotherapy (SBRT) is being increasingly used for the treatment of patients with lung cancer or lung metastasis who are medically unfit to undergo resection. In order to improve accuracy and confidence in targeting tumors, many centers rely on fiducial implantation. We evaluated the migration of a novel fiducial marker specifically designed for lung tissue implante...

متن کامل

Evaluation of different fiducial markers for image-guided radiotherapy and particle therapy

Modern radiotherapy (RT) techniques are widely used in the irradiation of moving organs. A crucial step in ensuring the correct position of a target structure directly before or during treatment is daily image guidance by computed tomography (CT) or X-ray radiography (image-guided radiotherapy, IGRT). Therefore, combinations of modern irradiation devices and imaging, such as on-board imaging (O...

متن کامل

Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance.

The purpose of this study is to assess the accuracy of day-to-day predictions of liver tumour position using implanted gold markers as surrogates and to compare the method with alternative set-up strategies, i.e. no correction, vertebrae and 3D diaphragm-based set-up. Twenty patients undergoing stereotactic body radiation therapy (SBRT) with abdominal compression for primary or metastatic liver...

متن کامل

Submillimetric target-registration error using a novel, non-invasive fiducial system for image-guided otologic surgery.

OBJECTIVE Otologic surgery is undertaken to treat ailments of the ear, including persistent infections, hearing loss, vertigo, and cancer. Typically performed on otherwise-healthy patients in outpatient facilities, the application of image-guided surgery (IGS) has been limited because accurate (<1 mm), non-invasive fiducial systems for otologic surgery have not been available. We now present su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Bio-Medical Materials and Engineering

سال: 2014

ISSN: 0959-2989,1878-3619

DOI: 10.3233/bme-141159