Field test of active night cooling supplied by district cooling in three commercial buildings

نویسندگان

چکیده

Several previous studies have investigated active night cooling strategies to reduce the peak load in buildings, primarily by precooling building ventilation air during night. In this study, is supplied use of district cooling, mainly for buildings hydronic systems, such as chilled beam or fan coil but potentially also cool if outdoor temperature above supply setpoint. A field test with was conducted summer 2020 three commercial located Gothenburg, Sweden. The strategy implemented changing time schedule operation buildings’ systems twenty-four hours per day first half and back regular schedules second half. results showed that failed hourly maximum power. However, load, corresponding 100 highest power, reduced 6.5% one buildings. Active daytime energy usage between 0.7 4.6%. demonstrated some associated are more compatible than others. it possible achieve power reductions simple measures. providing will cause additional costs owners unless incentivized provider.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of three commercial microclimate cooling systems.

Three commercially available microclimate cooling systems were evaluated for their ability to reduce heat stress in men exercising in a hot environment while wearing high insulative, low permeability clothing. Five male volunteers performed three 180-min experiments (three repeats of 10 min rest, 50 min walking at 440 watts) in an environment of 38 degrees C dry bulb (Tdb), 12 degrees C dew poi...

متن کامل

Night cooling of the ozonosphere.

Some estimate of the cooling of the ozonosphere can be made using the calculated solar energy absorbed in various layers. After sunset this source of energy is removed and cooling occurs mainly by radiation up and down. The conclusion is reached that during a night the cooling is about 30° C at 50 km. and only a fraction of a degree below 25 km. This means that the ozonosphere temperature inver...

متن کامل

Improved Night Cooling System for Home

This paper proposes a new approach of cooling system for home. The main advantages of this cooling system are it consumes very low power, no emission of harmful gas and support for health. The basic principle of the system is free cooling is taking place when the external ambient air entropy is less than the indoor air enthalpy and the cool external air is transferred to the building room direc...

متن کامل

Study on Auto-DR and Pre-cooling of Commercial Buildings with Thermal Mass in California

This paper discusses how to optimize pre-cooling strategies for buildings in a hot California climate zone with the Demand Response Quick Assessment Tool (DRQAT), a building energy simulation tool. This paper outlines the procedure used to develop and calibrate DRQAT simulation models, and applies this procedure to eleven field test buildings. The results of a comparison between the measured de...

متن کامل

Novel Active Transient Cooling Systems

Under this grant, we have conducted detailed studies of magnetocaloric nanomaterials for solid state cooling applications. Such materials are of great current interest, in fact, the current AFOSR MURI Topic #20 is exclusively devoted to solid state cooling. Our work on synthesis, characterization and property evaluation of magnetocaloric materials is summarized. Magnetic refrigeration systems o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2021

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202124611004