Film boiling heat transfer and minimum-heat-flux(MHF)-point condition in subcooled pool boiling.
نویسندگان
چکیده
منابع مشابه
Highly subcooled pool boiling heat transfer at various gravity levels
A microscale heater array 2:7 mm 2:7 mm in size along with a video camera was used to provide subcooled pool boiling heat transfer measurements at gravity levels ranging from 1.8g to 10 g. The fluid was FC-72 at 1 atm and subcooled by nominally 36 C for all cases. A Terrier–Orion sounding rocket and the KC-135 aircraft were used to provide the microgravity and low-g environments, respectively. ...
متن کاملExperimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...
متن کاملPool Boiling Heat Transfer in Water/Amines Solutions
In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...
متن کاملExperimental measurement of heat transfer coefficient and mass of deposited CaSO4 in subcooled flow boiling condition
Fouling is a common, fundamental and costly problem in heat transfer systems, which reduces thermal efficiency of equipment, increases the energy loss and causes strong damage to the heat transfer equipment in various industries. The main causes of fouling on the heat transfer surfaces are salts with inverse temperature-solubility in the fluid which calcium sulfate is one of the most important ...
متن کاملHeater size and heater aspect ratio effects on subcooled pool boiling heat transfer in low - g
Pool boiling heat transfer measurements using heaters of varying aspect ratio were obtained in low-g (0.01 g ± 0.025 g) aboard the KC-135 aircraft. The heater aspect ratio was varied by selectively powering 2 · 2, 2 · 4, 2 · 6, 2 · 8, and 2 · 10 arrays of heaters in a 10 · 10 heater array containing individual heaters 0.7 · 0.7 mm in size. Electronic control circuitry was used to maintain an is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JSME international journal
سال: 1987
ISSN: 0913-185X
DOI: 10.1299/jsme1987.30.1274