Film cooling adiabatic effectiveness measurements of pressure side trailing edge cooling configurations
نویسندگان
چکیده
منابع مشابه
Film Cooling Measurements for Novel Hole Configurations
The effect of film cooling slot exit area and shape is studied. Detailed heat transfer coefficient and film effectiveness measurements are obtained simultaneously using a single transient IR thermography technique. Two designs with a crescent shaped exit and a slot exit are considered. The results show that the crescent shaped exit provides significantly higher film cooling effectiveness than t...
متن کاملStudy of Trailing-Edge Cooling Using Pressure Sensitive Paint Technique
An experimental investigation was conducted to study the effects of blowing ratio and the existence of lands on the film cooling effectiveness of a turbine blade trailing-edge model. Instead of using a temperature-based technique, a mass transfer analogywas used to quantify the film cooling effectiveness. This was done through themeasurement of the distribution of oxygen concentration over the ...
متن کاملNumerical Simulation Of the Componend Angles Effects On Adiabatic Film Cooling Effectiveness
Abstract Film Cooling Adiabatic Effectiveness on a Profile of a Gas Turbine blade that Using Holes with 45 Degree Combined Angles to the Flow Direction and Radial Along the Attack Edge as well as 25 Degree Angles to the Flow Direction and Surface Area of the Attack Edge Area and 35 degrees relative to the outlet hole suefaces along stagnation line, Under a specified blowing ratios, using the Re...
متن کاملبررسی عددی تاثیرنسبت تزریق و زوایای انحرافی در عملکرد آدیاباتیک خنک کاری لایه ای
Film Cooling Adiabatic Effectiveness on a Specific Profile of a Gas Turbine blade that Using Holes with 25 and 45 Degree Combined Angles to the Flow Direction and Radial Along the Attack Edge as well as 25 Degree Angles to the Flow Direction and Surface Area of the Attack Edge Area , Under two different blowing ratios, using the Reynolds stress approach and the SST turbulence model, have been i...
متن کاملAdiabatic cooling of antiprotons.
Adiabatic cooling is shown to be a simple and effective method to cool many charged particles in a trap to very low temperatures. Up to 3×10(6) p are cooled to 3.5 K-10(3) times more cold p and a 3 times lower p temperature than previously reported. A second cooling method cools p plasmas via the synchrotron radiation of embedded e(-) (with many fewer e(-) than p in preparation for adiabatic co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Propulsion and Power Research
سال: 2015
ISSN: 2212-540X
DOI: 10.1016/j.jppr.2015.10.001