With this report we aim to make available a standard operating procedure (SOP) developed for RNA stabilization of small blood volumes collected via a finger stick. The anticipation that this procedure may be improved through peer-review and/or readers public comments is another element motivating the publication of this SOP. Procuring blood samples from human subjects can, among other uses, ena...
متن کاملCollection and storage of human blood cells for mRNA expression profiling: a 15-month stability study.
mRNA Expression Profiling: A 15-Month Stability Study, Jean-Brice Marteau, Steve Mohr, Michèle Pfister, and Sophie Visvikis-Siest (Institut National de la Santé et de la Recherche Médicale, U525 Equipe 4, Faculté de Pharmacie, Nancy, France; * address correspondence to this author at: INSERM U525 Equipe 4, 30 rue Lionnois, 54000 Nancy, France; fax 33-3-83321322, e-mail Sophie.VisvikisSiest@nanc...
متن کاملSpecial collection and storage tubes for blood endotoxin and cytokine measurements.
Commercially available blood-collection tubes may be contaminated with endotoxin (315 +/- 95 pg/tube) and could therefore be unsuitable for blood collection for endotoxin measurement. Plasma separation and storage are a potential source of contamination. To avoid contamination and error, we have developed new blood collection tubes that contain heparin free of endotoxin (LPS) and a gel to separ...
متن کاملEffects of storage, RNA extraction, genechip type, and donor sex on gene expression profiling of human whole blood.
BACKGROUND Gene expression profiling of whole blood may be useful for monitoring toxicological exposure and for diagnosis and monitoring of various diseases. Several methods are available that can be used to transport, store, and extract RNA from whole blood, but it is not clear which procedures alter results. In addition, characterization of interindividual and sex-based variation in gene expr...
متن کاملEffects of storage and type of blood collection tubes on hepatitis C virus level in whole blood samples.
In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum H...