First Evidence of Multiple $\beta $-delayed Neutron Emission for Isotopes with $A>100$
نویسندگان
چکیده
منابع مشابه
β-decay half-lives and β-delayed neutron emission probabilities for several isotopes
R. Caballero-Folch,1,2,* C. Domingo-Pardo,3 J. Agramunt,3 A. Algora,3,4 F. Ameil,5 Y. Ayyad,6 J. Benlliure,6 M. Bowry,7 F. Calviño,1 D. Cano-Ott,8 G. Cortès,1 T. Davinson,9 I. Dillmann,2,5,10 A. Estrade,5,11 A. Evdokimov,5,10 T. Faestermann,12 F. Farinon,5 D. Galaviz,13 A. R. García,8 H. Geissel,5,10 W. Gelletly,7 R. Gernhäuser,12 M. B. Gómez-Hornillos,1 C. Guerrero,14,15 M. Heil,5 C. Hinke,12 ...
متن کاملFirst Measurement of Several β-Delayed Neutron Emitting Isotopes Beyond N=126.
The β-delayed neutron emission probabilities of neutron rich Hg and Tl nuclei have been measured together with β-decay half-lives for 20 isotopes of Au, Hg, Tl, Pb, and Bi in the mass region N≳126. These are the heaviest species where neutron emission has been observed so far. These measurements provide key information to evaluate the performance of nuclear microscopic and phenomenological mode...
متن کاملThe neutron long counter NERO for studies of b delayed neutron emission in the r-process
The neutron long counter NERO was built at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University, for measuring b delayed neutron-emission probabilities. The detector was designed to work in conjunction with a b delay implantation station, so that b decays and b delayed neutrons emitted from implanted nuclei can be measured simultaneously. The high efficiency of ab...
متن کاملA Preliminary Comparison of MCNP6 Delayed Neutron Emission from
A Description of the Experiment The DNC system at RMCC uses the SLOWPOKE-2 reactor [2] as a source of neutrons. Samples containing 235 U were prepared as acidified aqueous solutions from certified reference standards (natural U standard CRM 4321C, NIST, Gaithersburg, MD, and depleted U standard CRM U005A 0.5064 ± 0.0003 atom% U, New Brunswick Laboratory, Argonne, IL). Each solution was containe...
متن کاملExploring Neutron-Rich Oxygen Isotopes with MoNA
The Modular Neutron Array (MoNA) was used in conjunction with a large-gap dipole magnet (Sweeper) to measure neutron-unbound states in oxygen isotopes close to the neutron dripline. While no excited states were observed in 24O, a resonance at 45(2) keV above the neutron separation energy was observed in 23O.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Physica Polonica B
سال: 2017
ISSN: 0587-4254,1509-5770
DOI: 10.5506/aphyspolb.48.517