Fixation Stability and Stiffness of Two Implant Systems for Proximal Femoral Varization Osteotomy
نویسندگان
چکیده
منابع مشابه
A Modified Technique of Fixation for Proximal Femoral Valgus Osteotomy in Abnormal Bone: A Report of Two Cases
The ideal size of intramedullary device to fix corrective osteotomy of proximal femur in abnormal bone in children and small patients may not be easily available. We report the successful use of Rush rod in combination with multiple Kirschner wires to fix the corrective osteotomy of coxa vara and shepherd crook deformity in two patients with osteogenesis imperfecta and fibrous dysplasia. The un...
متن کاملBiomechanical optimization of different fixation modes for a proximal femoral L-osteotomy
BACKGROUND Numerous proposed surgical techniques have had minimal success in managing greater trochanter overgrowth secondary to retarded growth of the femoral capital epiphysis. For reconstruction of residual hip deformities, a novel type of proximal femur L-osteotomy was performed with satisfactory results. Although the clinical outcome was good, the biomechanical characteristics of the femur...
متن کاملLCP 140° Pediatric Hip Plate for fixation of proximal femoral valgisation osteotomy
PURPOSE Femoral osteotomy is one of the most widely performed reconstructive operations in pediatric orthopedic surgery. Many implants for fixation have been used, but so far there is no literature about the application and outcome of the LCP 140° Pediatric Hip Plate for proximal femoral valgisation in children. METHODS Data of patients with a valgisation of the proximal femur using the LCP 1...
متن کاملTension Band Wiring for Proximal Femoral Varus Osteotomy Fixation in Children
For proximal varus osteotomy of the femur in children, a stable fixation, is a concern regarding the safety and the protection of the surgery. The methods of fixation are mostly represented by plating systems; however, the tension band wiring is a simple and eligible option for fixation of proximal femur osteotomy. The purpose of this retrospective case series study is to evaluate outcomes and ...
متن کاملTwin hook fixation for proximal femoral fractures.
PURPOSE To report results of twin hook fixation for proximal femoral fractures in comparison to those fixed with the conventional lag screw. METHODS Between August 2005 and July 2006, 2 men and 15 women aged 74 to 94 (mean, 85) years with proximal femoral fractures underwent open reduction and internal fixation using the twin hook system. The tip-apex distance was compared with that in 20 pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Sciences
سال: 2020
ISSN: 2076-3417
DOI: 10.3390/app10175867