Flashover Performance of contaminated HV Outdoor Insulators in Egypt

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computation of AC flashover voltage of polluted HV insulators using a dynamic arc model

Flashover of polluted insulators is still a serious threat to the safe operation of a power transmission system. Despite the extensive investigations carried out on the pollution performance of the insulators, the flashover characteristics are not well understood. Recent theoretical and experimental research on polluted insulators is yet to yield a perfect generalized mathematical model which c...

متن کامل

DC Flashover Performance of Ice-Covered Composite Insulators with Parallel Air Gaps

DC flashover performance of ice-covered composite insulators with a parallel air gap (CI/PAG) is an important technical consideration when such insulators are used to isolate ground wires for the purpose of DC ice-melting. Tests on tension and suspension types of CI/PAG were thus carried out in the artificial climate chamber to investigate their DC icing flashover performance. The influences of...

متن کامل

Designation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.

Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...

متن کامل

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

Flashover Characteristics of Silicone Rubber Sheets under Various Environmental Conditions

Silicone rubber insulators are replacing the conventional ceramic and porcelain insulators rapidly in power transmission and distribution industry. Very limited field knowledge is available about the performance of silicone rubber insulators in polluted and contaminated environments and therefore need further investigation. A comprehensive analysis of silicone rubber sheets (intended for coatin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The International Conference on Electrical Engineering

سال: 2014

ISSN: 2636-4441

DOI: 10.21608/iceeng.2014.30459