Flexible cotton-AuNP thread electrode for non-enzymatic sensor of uric acid in urine

نویسندگان

چکیده

We report on the development of an electrochemical sensor platform based modified cotton fibers for non-enzymatic detection uric acid (UA), important biomarker gout disease. To create flexible electrode, a thread was coated with carbon ink as pre-conductive layer prior to direct electrodeposition AuNPs. Then, differential pulse voltammetry (DPV) used evaluate performances, and linear range between 10 µM 5.0 mM obtained. The has limit 0.12 µM, which is sufficient use in patients suffering from disease higher than 4.46 mM. Furthermore, we found that sensitivity not affected by presence other physiological compounds present human urine. described potential integration diaper hence enabling rapid screening

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nile Blue- Chitosan Composite as a new Electrochemical Sensor for Uric Acid on Glassy Carbon Electrode

Nile blue-Chitosan NB-CH as a new type of organic days-organic composite was made using Nile blue and chitosan. The NB-CH composite was made using a 0.005 M solution of Nile blue NB and a 7 solution of chitosan. To do this, a mixture of Nile blue and Chitosan with the ratio of 2:1 was prepared. The electrocatalytic oxidation of uric acid UA has been studied on glassy carbon electrode by NB-CH u...

متن کامل

Flexible wire-shaped strain sensor from cotton thread for human health and motion detection

In this work, a wire-shaped flexible strain sensor was fabricated by encapsulating conductive carbon thread (CT) with polydimethylsiloxane (PDMS) elastomer. The key strain sensitive material, CT, was prepared by pyrolysing cotton thread in N2 atmosphere. The CT/PDMS composite wire shows a typical piezo-resistive behavior with high strain sensitivity. The gauge factors (GF) calculated at low str...

متن کامل

Urate oxidase electrode based on dissolved oxygen probe for urine uric acid determination.

A biosensor for the specific determination of uric acid in urine was developed using urate oxidase (EC 1.7.3.3) in combination with a dissolved oxygen probe. Urate oxidase was immobilized with gelatin by means of glutaraldehyde and fixed on a pretreated teflon membrane to serve as enzyme electrode. The electrode response was maximum when 50 mM glycine buffer was used at pH 9.2 and 35 degrees C....

متن کامل

Fabrication of Graphene–LaMnO3 Sensor for Simultaneous Electrochemical Determination of Dopamine and Uric Acid

Dopamine  (DA)  and  uric  acid  (UA)  are  two  of  important bimolecular widely  circulated  in  body blood. Therefore, development of simple and rapid methods for simultaneous determination of them in  routine  analysis  has  a  great  significance  for  many  researchers. Therefore,  for  the  first  time, nanocomposite  of  graphene  (Gr)LaMnO3has  been  utilized  to  fabricate  the  new  ...

متن کامل

Manganese Ferrite Nanocomposite Modified Electrochemical Sensor for the Detection of Guanine and Uric Acid

Manganese ferrite nanoparticles were produced by applying the combustion technique using the manganese acetate and ferric nitrate as the starting material. Analytical techniques like FESEM and TEM were utilized to characterize the synthesized materials. The typical size was observed in the range of 12 to 14 nm with a cubic structure. The synthesized material was used as an electrochemical senso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cellulose

سال: 2021

ISSN: ['1572-882X', '0969-0239']

DOI: https://doi.org/10.1007/s10570-021-04169-y