Flow Boiling Heat Transfer to a Dielectric Coolant in a Microchannel Heat Sink

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Dissolved Air on Subcooled Flow Boiling of a Dielectric Coolant in a Microchannel Heat Sink

The effects of dissolved air in the dielectric liquid FC-77 on flow boiling in a microchan-nel heat sink containing ten parallel channels, each 500 ␮m wide and 2.5 mm deep, were experimentally investigated. Experiments were conducted before and after degas-sing, at three flow rates in the range of 30– 50 ml/ min. The dissolved air resulted in a significant reduction in wall temperature at which...

متن کامل

Subcooled two-phase flow boiling in a microchannel heat sink: comparison of conventional numerical models

Subcooled flow boiling in multi-microchannels can be used as an efficient thermal management approach in compact electrical devices. Highly subcooled flow boiling of HFE 7100 is studied in two microchannel heat sinks to choose a proper numerical model for simulating boiling flows in microchannels. Results of five different numerical models, including Volume of Fluid (VOF), Eulerian boiling, Eul...

متن کامل

Microchannel size effects on local flow boiling heat transfer to a dielectric fluid

Heat transfer with liquid–vapor phase change in microchannels can support very high heat fluxes for use in applications such as the thermal management of high-performance electronics. However, the effects of channel cross-sectional dimensions on the two-phase heat transfer coefficient and pressure drop have not been investigated extensively. In the present work, experiments are conducted to inv...

متن کامل

Experimental study of convective heat transfer coefficient of MgO nanofluid in a cylindrical microchannel heat sink

Convective heat transfer of MgO-water nanofluid in a microchannel heat sink is experimentally investigated in various concentrations of 0.01, 0.05, 0.1, and 0.6 wt%. The microchannel consisted of 48 parallel rectangular cross section channels with the height of 800 µm, width of 524 µm and length of 52 mm. A well stability duration (ca. 1 month) was resulted by a 180 min ultra-sonication of the ...

متن کامل

Local Heat Transfer Distribution and Effect of Instabilities During Flow Boiling in a Silicon Microchannel Heat Sink

Flow boiling of the perfluorinated dielectric fluid FC-77 in a silicon microchannel heat sink is investigated. The heat sink contains 60 parallel microchannels each of 100 m width and 389 m depth. Twenty-five evenly distributed temperature sensors in the substrate yield local heat transfer coefficients. The pressure drop across the channels is also measured. Experiments are conducted at five ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Components and Packaging Technologies

سال: 2007

ISSN: 1521-3331

DOI: 10.1109/tcapt.2007.892063