Flow Injection with Inhibited Chemiluminescence Method for the Determination of Dopamine Hydrochloride

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of phenylephrine hydrochloride by flow injection analysis with chemiluminescence detection.

A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80 degrees C. The calibration graph is linear over the range 0.03-8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ...

متن کامل

Development of a sensitive flow injection-chemiluminescence detection method for the indirect determination of propranolol

A highly sensitive flow injection-chemiluminescence detection (FI-CL) method based on pyrogallol (Pg) chemiluminescent reagent (CLreagent) oxidized by periodate for the determination of propranolol is presented. The presented method is an indirect CL detection method based on the CL emission generated during the oxidation of Pg with the excess of periodate that remains after oxidation of propra...

متن کامل

Flow injection chemiluminescence analysis for highly sensitive determination of noscapine

Noscapine is an antitussive drug and possesses potent antitumor activity. This work establishes a highly sensitive method for its determination by flow injection chemiluminescence (CL) technique. This method is based on its strong sensitizing effect on the weak CL reaction between sulfite and acidic permanganate. The mechanism for the sensitizing process is proposed on the basis of fluorescence...

متن کامل

Determination of Total Antioxidant Activity of Wines Using a Flow Injection Method with Chemiluminescence Detection

Total antioxidant capacity (TAC) of several samples of red and white wines was investigated by means of a new analysis method of flow injection with chemiluminescence detection ((FIA-CL). The applied method is based on a chemiluminescence reaction between luminol and hydroxyl radicals generated by the hydrogen peroxide in the presence of Co(II) ions complexed with ethylene diamine tetraacetic a...

متن کامل

Flow-injection Post-chemiluminescence Determination of Furazolidone in Animal Feeds

The post-chemiluminescence (PCL) reaction was observed with the mixture solution after completion CL reaction of luminol-H2O2 in present of Furazolidone (FZD). A novel method for the determination of FZD was established by flow-injection PCL. The CL intensity responded linearly to the concentration of FZD in the range 1.0×10 −7 -1.0×10 −5 g mL -1 , with a linear correlation of 0.9949. The detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2004

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.20.315