Analysis of variance of nanofluid heat transfer data for forced convection in horizontal spirally coiled tubes

In the present study, an experimental study is carried out to investigate the effect of adding Al and Cu nanoparticles to the base fluid (water) on the heat transfer rate in a spirally coiled tube. The spirally coiled tube is fabricated from the straight copper tube with the inner and outer coil diameters of 100 and 420 mm, respectively. The experiments have been done for water and two types of...

متن کامل

Forced Convection: Heat Transfer from Copper Cylinders to Air

Three copper cylinders of diameter 1/4”, 3/8” and1/2” were heated and then immersed in an air stream flowing through a cylindrical pipe. The temperature change of the cylinders with respect to time was measured at different air flow rates. With this data, the Nusselt, Reynolds and Prandtl numbers were calculated and correlated. This correlation was compared to ones established by Sherwood-Pigfo...

متن کامل

Heat Transfer Study of Perforated Fin under Forced Convection

Fins are protrusions on a heat transfer surface to augment heat transfer rate from it. The increase in area exposed to convection in case of finned surfaces results in increased heat transfer rate. In this study heat transfer characteristics of a pin fin with perforation is numerically analyzed. A pin fin is fabricated and experiments are done under forced convection conditions. The experimenta...

متن کامل

Natural Convection Heat Transfer from two Horizontal Cylinders

Natural convection heat transfer from a single horizontal cylinder and a pair of vertically aligned horizontal cylinders is investigated. Surface heat transfer distributions around the circumference of the cylinders are presented for Rayleigh numbers of 2 x 10, 4 x 10 and 6 x 10 and a range of cylinder spacings of 1.5, 2 and 3 diameters. With a cylinder pairing the lower cylinder is unaffected ...

متن کامل

Natural Convection Heat Transfer From Horizontal Cylinders in a Vertical Arra Confined Between Parallel Walls

Laminar natural convection from an array of horizontal isothermal cylinders confined between two vertical walls, at low Rayleigh numbers, is investigated by theoretical and numerical methods. The height of the walls is kept constant, however, number of the cylinders and their spacing, the distance between the walls and Rayleigh number have been varied. The optimal spacing (confining walls) and ...