Introduction. We present a case of a metallic foreign body embedded in the anterior chamber angle. After standing in close proximity to a construction worker breaking a tile, a 26-year-old woman using soft contact lens for the correction of mild myopia presented to emergency department for evaluation of a foreign body sensation of her right eye. Methods and Results. Diagnosis was confirmed by g...

متن کامل

Presenting as an anterior chamber foreign body

A woman aged 31, first seen in April, i969, had recently come to live in England from India. She complained of poor vision in the right eye and of a divergent squint. Her vision had been poor since early childhood, particularly in the right eye, and there had ceased to be useful vision in the right eye at the age of 20. An operation had been performed on the right eye under local anaesthesia wh...

متن کامل

Anterior Chamber Angle Assessment Techniques

The anterior chamber angle is the actual anatomical angle created by the root of the iris and the peripheral corneal vault. Within it lie the structures involved in the outflow passage of the aqueous, namely the trabecular meshwork and the Schlemm’s canal (figure 1). The depth of the angle in a healthy eye is approximately 30°, with the superior part usually less deep than the inferior half. Ho...

متن کامل

Anterior chamber depth in open angle glaucoma.

Anterior chamber depth was measured in patients with primary open angle glaucoma, low tension glaucoma, pigmentary dispersion syndrome, and glaucoma suspects. Multiple linear regression analysis demonstrated that anterior chamber depth is a function of sex, age, and refractive error. Values for anterior chamber depth corrected for age and refractive error were greater in patients with pigmentar...

متن کامل

Automated analysis of angle closure from anterior chamber angle images.

PURPOSE To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. METHODS In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classifi...