Forward-viewing resonant fiber-optic scanning endoscope of appropriate scanning speed for 3D OCT imaging

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forward-viewing resonant fiber-optic scanning endoscope of appropriate scanning speed for 3D OCT imaging

A forward-viewing resonant fiber-optic endoscope of a scanning speed appropriate for a high-speed Fourier-domain optical coherence tomography (FD-OCT) system was developed to enable real-time, three-dimensional endoscopic OCT imaging. A new method was explored to conveniently tune the scanning frequency of a resonant fiber-optic scanner, by properly selecting the fiber-optic cantilever length, ...

متن کامل

Scanning single-mode fiber optic catheter-endoscope for optical coherence tomography.

We describe a new optical coherence tomography catheter-endoscope for micrometer-scale, cross-sectional imaging in internal organ systems. The catheter-endoscope uses single-mode fiber optics with a novel transverse scanning design. The distal end of the catheter-endoscope uses a gradient-index lens with a microprism to emit and collect a single spatial-mode optical beam with specific focusing ...

متن کامل

Forward Viewing OCT

The author hereby grants to MIT permission to reproduce and to distribute publicly paper and electronic copies of this thesis document in whole or in part in any medium now known or hereafter created.

متن کامل

Depth Enhancement using a Scanning Fiber Optical Endoscope

The Single Fiber Scanning Endoscope (SFSE) is a miniature endoscope with unique features that promises to open new minimally invasive procedures for previously inaccessible diseases. There is a need for enhancement of depth cues and 3D measurement in procedures using monoscopic endoscopes. The SFSE uses scanning acquisition that gives it unique imaging properties which are advantageous for 3D v...

متن کامل

Distortion-free freehand-scanning OCT implemented with real-time scanning speed variance correction

Hand-held OCT systems that offer physicians greater freedom to access imaging sites of interest could be useful for many clinical applications. In this study, by incorporating the theoretical speckle model into the decorrelation function, we have explicitly correlated the crosscorrelation coefficient to the lateral displacement between adjacent A-scans. We used this model to develop and study a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2010

ISSN: 1094-4087

DOI: 10.1364/oe.18.014375