Four-dimensional Flow MRI: Principles and Cardiovascular Applications

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four-dimensional flow MRI using spiral acquisition.

Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to reduce the scan time of four-dimensional flow MRI without sacrificing quality. ...

متن کامل

MRI: Basic Principles and Applications

In the second chapter and throughout the book, Dr. Gustavii identifies common problems of non-native English speakers, a topic overlooked in Day's book. Even native English writers will benefit from his clarifications and suggestions, such as avoiding the use of "respectively" and "and/or." Another strength of the book is the cogent discussion of which researchers on a project deserve authorshi...

متن کامل

Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review

BACKGROUND Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology used to visualise and quantify intra-cardiac blood flow. The aim of this systematic review is to assess the literature on the current clinical applications of intra-cardiac 4D flow CMR. METHODS A systematic review was conducted to evaluate the literature on the intra...

متن کامل

Assessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI.

PURPOSE To explore the use of MR-estimated turbulence quantities for the assessment of turbulent flow effects on the vessel wall. METHODS Numerical velocity data for two patient-derived models was obtained using computational fluid dynamics (CFD) for two physiological flow rates. The four-dimensional (4D) Flow MRI measurements were simulated at three different spatial resolutions and used to ...

متن کامل

Cardiovascular Applications of Hyperpolarized MRI

Many applications of MRI are limited by an inherently low sensitivity. Previous attempts to overcome this insensitivity have focused on the use of MRI systems with stronger magnetic fields. However, the gains that can be achieved in this way are relatively small and increasing the magnetic field invariably leads to greater technical challenges. More recently, the development of a range of techn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: RadioGraphics

سال: 2019

ISSN: 0271-5333,1527-1323

DOI: 10.1148/rg.2019180091