Frequency map analysis applied to the als storage ring

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lattice Model Calibration and Frequency Map Measurements at the ALS

To understand the dynamics in an accelerator it is essential to have a good model representing its realistic lattice. One method used at the ALS to calibrate the linear (coupled) accelerator model is the analysis of orbit response matrices. Recently this method has been combined with frequency map techniques, both in tracking and experiment at the accelerator. Comparing the results of simulated...

متن کامل

Generalized Morphological Operators Applied to Map-Analysis

The concept of strictness of morphological operators is discussed, and it is shown that the ordinary morphological operators have extreme strictness which leads to sensitivity to noise and digital artifacts. Based on this observation new morphological operators that generalize the ordinary morphological operators, are de ned. The generalized operators have controllable strictness and so excessi...

متن کامل

Experimental Frequency Maps for the Esrf Storage Ring

Experimental frequency maps have already revealed unknown characteristics of the ESRF storage ring non-linear dynamics. In the past year, several efforts were undertaken in order to establish this technique as an operational online tool. The acquisition time was significantly reduced by collecting data from a dedicated fast BPM system. The problem of beam decoherence was limited by establishing...

متن کامل

Synchrotron Frequency Splitting in the Slac Storage Ring

Introduction The values of the other m " , are determined by

متن کامل

Analysis and Design Modifications for Upgrade of Storage Ring Bump Pulse System Driving the Injection Bump Magnets at the Als*

A fast (4.0 ms half period) resonant discharge pulse system, using SCRs, was designed and constructed to drive the injection bump magnet system at the Advanced Light Source (ALS)[1]. The commissioning process revealed a high frequency resonance (T = 800 NS) superimposed on the driver discharge wave form. In addition, the peak amplitude of the magnet load recovery current exceeded design specifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Synchrotron Radiation News

سال: 2000

ISSN: 0894-0886,1931-7344

DOI: 10.1080/08940880008261114