Frequency Response From Solar PV: A Dynamic Equivalence Closed-Loop System Identification Approach

نویسندگان

چکیده

The analysis of the frequency response integrated transmission-distribution networks with deep penetration solar photovoltaic (PV) generation faces major challenges due to complexity emerging from dynamic models numerous and diverse PV units involved. This article proposes converter-based equivalent for both distributed (distribution network-connected) large-scale (transmission units, which take into account practical issues, such as measurement coordination delays. Different previous work that adopted an open-loop identification, unknown model parameters are identified here through a novel closed-loop identification process based on least-square minimization. allows capturing continuous interaction between system responses, thus improving outcome overall model. proposed validated real data August 2018 separation event in Australia. results demonstrate excellent performance determining transmission distribution networks, hence paving way its adoption stability low-carbon grids dominated by frequency-responsive renewables.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Bayesian Approach to Closed-loop System Identification

The challenging issue of identifying a closed-loop system from short and/or non-informative data records is addressed. A bayesian approach is developed within this framework. It is shown that accurate estimates and realistic confidence intervals can be obtained by taking into account prior knowledge on the system. The performances of the proposed method are illustrated with a simulation example...

متن کامل

A New Approach in Preliminary Design of Closed Loop Solar Thermal Systems (RESEARCH NOTE)

In this paper, a model for closed loop solar system is presented and an attempt is made to generalize the model to be utilized for primary design of any solar active thermal system. This model may be used for systems in which gas or a liquid are fluids that flow. Two new parameters, namely, the system heat delivery factor and the system heat absorption factor are introduced in the model. These ...

متن کامل

On validating closed-loop behaviour from noisy frequency-response measurements

It is shown how noisy closed-loop frequency response measurements can be used to obtain pointwise in frequency bounds on the possible difference between an otherwise unknown closed-loop system and the closed-loop comprising a nominal model of the plant and a stabilising controller. To this end, the Vinnicombe’s gap metric framework for robustness analysis plays a central role. Indeed, an optimi...

متن کامل

Asymptotic Equivalence of Certain Closed Loop Subspace Identification Methods

Subspace identification for closed loop systems has been recently studied by several authors. Even though results are available which allows to compute the asymptotic variance of the estimated parameters for several algorithms, less clear is the situation as to relative performance is concerned. In this paper we partly answer this last question showing that the SSARX algorithm introduced by Jan...

متن کامل

Closed-Loop System Identification with Genetic Algorithms

High-performance control design for a flexible space structure is challenging as highfidelity plant models are difficult to obtain a priori. Uncertainty in the control design models typically require a very robust, low-performance control design, which must be tuned onorbit to achieve the required performance. Closed-loop system identification is often required to obtain a multivariable open-lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Systems Journal

سال: 2022

ISSN: ['1932-8184', '1937-9234', '2373-7816']