Frequency Stability of Isolated Hydropower Plant with Surge Tank Under Different Turbine Control Modes

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability Analysis of a Run-of-River Diversion Hydropower Plant with Surge Tank and Spillway in the Head Pond

Run-of-river hydropower plants usually lack significant storage capacity; therefore, the more adequate control strategy would consist of keeping a constant water level at the intake pond in order to harness the maximum amount of energy from the river flow or to reduce the surface flooded in the head pond. In this paper, a standard PI control system of a run-of-river diversion hydropower plant w...

متن کامل

Governor Design for a Hydropower Plant with an Upstream Surge Tank by GA-Based Fuzzy Reduced-Order Sliding Mode

This paper investigates governor design by reduced-order sliding mode for a hydropower plant with an upstream surge tank. The governing system is made up of a tunnel, a surge tank, a penstock, a wicket gate and servomechanism, a governor, a hydro-turbine and a grid. Concerning the components of the governing system, their mathematic models are established. Then, these models are interconnected ...

متن کامل

Hydraulic Transients in the Long Diversion-Type Hydropower Station with a Complex Differential Surge Tank

Based on the theory of hydraulic transients and the method of characteristics (MOC), a mathematic model of the differential surge tank with pressure-reduction orifices (PROs) and overflow weirs for transient calculation is proposed. The numerical model of hydraulic transients is established using the data of a practical hydropower station; and the probable transients are simulated. The results ...

متن کامل

Failures during Load-Frequency Control Maneuvers in an Upgraded Hydropower Plant: Causes, Identification of Causes and Solution Proposals

The objective of this paper is to investigate the cause of several unexpected high amplitude oscillations that occurred in the surge tank water level of a real hydropower plant during secondary load-frequency control (LFC) maneuvers, after the replacement of the turbine runner, and to propose solutions that allow the power plant to continue providing secondary LFC in a safe and reliable manner....

متن کامل

Analysis of the Primary Control System of a Hydropower Plant in Isolated Model

The aim of this work is to study the primary control system of a hydropower plant in isolated mode. The power plant is modeled by differential equations and results are compared to field data from an actual hydropower plant, presenting deviations lower than 1.0%. The study of primary control system is conducted in order to define useful sets of parameters for controllers. Four controllers are s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electric Power Components and Systems

سال: 2015

ISSN: 1532-5008,1532-5016

DOI: 10.1080/15325008.2015.1049722