Fresh gas requirements during spontaneous ventilation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fresh gas requirements of an enclosed afferent reservoir breathing system during controlled ventilation in children.

An enclosed afferent reservoir breathing system (EAR) designed by Ohmeda was evaluated during anaesthesia with controlled ventilation in 104 healthy children. Carbon dioxide production and arterial carbon dioxide tension were measured in 12 children in order to determine the proportion of fresh gas (VF) involved in gas exchange. When the ratio of minute volume ventilation to fresh gas flow (VE:...

متن کامل

Gas exchange during mechanical ventilation and spontaneous breathing. Intermittent mandatory ventilation after open heart surgery.

Pulmonary gas exchange rates in eight patients after open heart surgery were studied during weaning from the ventilator. We investigated continuous positive pressure ventilation (CPPV), intermittent mandatory ventilation (IMV) and spontaneous breathing with continuous positive airway pressure (CPAP). During each mode of ventilation we measured: CO2 production (VCO2), O2 consumption (VO2), cardi...

متن کامل

Comparison of ventilation and gas exchange in anaesthetized infants and children during spontaneous and artificial ventilation.

Measurements of minute and alveolar ventilation (VE and VA), respiratory frequency, end-tidal carbon dioxide concentration (E'CO2), deadspace (VD) and carbon dioxide output (VCO2) were made in 22 anaesthetized infants and young children during spontaneous (SV) and intermittent positive pressure ventilation (IPPV). In the children who had been given an opioid premedication, E'CO2 concentrations ...

متن کامل

Fresh gas flow requirements using the ADE anaesthetic system during late pregnancy.

Thirty-two pregnant patients at term undergoing elective Caesarean section were ventilated with a non-co-axial ADE anaesthetic system (E mode) supplied with fresh gas flows (FGF) of either 70 or 100 ml kg-1 min-1, on a random basis. Ventilation with an FGF of 70 ml kg-1 min-1 produced mean PaCO2 and PE' CO2 values of 6.48 +/- 1.15 kPa and 6.41 +/- 0.76 kPa, respectively. Patients were thus hype...

متن کامل

Increased ventilation requirements during obstetric general anaesthesia.

The inspiratory fresh gas flow rate (FGF) required to produce an end-tidal carbon dioxide tension (PE'CO2) of 4 kPa during general anaesthesia, neuromuscular blockade and artificial ventilation, was compared in a group of 46 obstetric patients and a matched group of 50 non-pregnant female patients. The non-pregnant patients required a mean (SD) inspiratory FGF of 77 (10.6) ml kg-1 min-1, wherea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 1994

ISSN: 0007-0912

DOI: 10.1093/bja/73.1.121-b