Fringe analysis: single-shot or two-frames? Quantitative phase imaging answers
نویسندگان
چکیده
منابع مشابه
Noninterferometric single-shot quantitative phase microscopy.
We present a noninterferometric single-shot quantitative phase microscopy technique with the use of the transport of intensity equation (TIE). The optical configuration is based on a Michelson-like architecture attached to a nonmodified inverted transmission bright field microscope. Two laterally separated images from different focal planes can be obtained simultaneously by a single camera expo...
متن کاملSingle-shot quantitative dispersion phase microscopy.
We present an imaging modality capable of providing high-speed optical dispersion measurements of live cells. The technique permits wide-field measurement of the optical phase shifts introduced by a sample for multiple discrete wavelengths in a single image capture. Utilizing spatial modulation and the wavelength dependence of the interference-fringe spacing, average refractive index as a funct...
متن کاملSingle-Shot Smartphone-Based Quantitative Phase Imaging Using a Distorted Grating
Blood testing has been used as an essential tool to diagnose diseases for decades. Recently, there has been a rapid developing trend in using Quantitative Phase Imaging (QPI) methods for blood cell screening. Compared to traditional blood testing techniques, QPI has the advantage of avoiding dyeing or staining the specimen, which may cause damage to the cells. However, most existing systems are...
متن کاملAccurate single-shot quantitative phase imaging of biological specimens with telecentric digital holographic microscopy.
The advantages of using a telecentric imaging system in digital holographic microscopy (DHM) to study biological specimens are highlighted. To this end, the performances of nontelecentric DHM and telecentric DHM are evaluated from the quantitative phase imaging (QPI) point of view. The evaluated stability of the microscope allows single-shot QPI in DHM by using telecentric imaging systems. Quan...
متن کاملSingle-shot quantitative perfusion imaging of the human lung.
The major drawback to quantitative perfusion imaging using arterial spin labeling (ASL) techniques is the need to acquire two images (tag and control), which must be subtracted in order to obtain a perfusion-weighted image. This can potentially result in misregistration artifacts, especially in lung imaging, due to varying lung inflation levels in different breath-holds. In this work a double i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2021
ISSN: 1094-4087
DOI: 10.1364/oe.423336