From street canyon microclimate to indoor environmental quality in naturally ventilated urban buildings: Issues and possibilities for improvement

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indoor Environmental Quality in Mechanically Ventilated, Energy-Efficient Buildings vs. Conventional Buildings

Energy-efficient buildings need mechanical ventilation. However, there are concerns that inadequate mechanical ventilation may lead to impaired indoor air quality. Using a semi-experimental field study, we investigated if exposure of occupants of two types of buildings (mechanical vs. natural ventilation) differs with regard to indoor air pollutants and climate factors. We investigated living a...

متن کامل

Urban Canyon Microclimate and Spatial Behavior in Extreme Climate Situations (Case Study: Downtown Pedestrian Street in Northern China)

Microclimate in open space affected by the urban layout and spatial forms plays an important role in the outdoor comfort, thus the outdoor activities based on the comfort sensation will directly affected by the spatial forms. An outstanding open space should satisfy different requirements of outdoor activities and create relatively comfortable place.Most studies have been conducted on the...

متن کامل

Indoor Air Quality in Naturally Ventilated Italian Classrooms

Characterization of indoor air quality in school classrooms is crucial to children’s health and performance. The present study was undertaken to characterize the indoor air quality in six naturally ventilated classrooms of three schools in Cassino (Italy). Indoor particle number, mass, black carbon, CO2 and radon concentrations, as well as outdoor particle number were measured within school hou...

متن کامل

Transport Phenomena in the Urban Street Canyon

1 Abstract A generic proecological traffic control model for the urban street canyon is proposed by development of advanced continuum field hydrodynamical control model of the street canyon. The model of optimal control of street canyon dynamics is also investigated. The mathematical physics' approach (Eulerian approach) to vehicular movement, to pollutants' emission, and to pollutants' dynamic...

متن کامل

Case study investigation of indoor air quality in mechanically ventilated and naturally ventilated UK social housing

There is a significant lack of indoor air quality research in low energy homes. This study compared the indoor air quality of eight newly built case study homes constructed to similar levels of air-tightness and insulation; with two different ventilation strategies (four homes with Mechanical Ventilation with Heat Recovery (MVHR) systems/Code level 4 and four homes naturally ventilated/Code lev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Building and Environment

سال: 2015

ISSN: 0360-1323

DOI: 10.1016/j.buildenv.2015.10.008