Full range complex spectral domain optical coherence tomography without additional phase shifters
نویسندگان
چکیده
منابع مشابه
Full-range k-domain linearization in spectral-domain optical coherence tomography.
A full-bandwidth k-domain linearization method for spectral-domain optical coherence tomography (SD-OCT) is demonstrated. The method uses information of the wavenumber-pixel-position provided by a translating-slit-based wavelength filter. For calibration purposes, the filter is placed either after a broadband source or at the end of the sample path, and the filtered spectrum with a narrowed lin...
متن کاملFull range polarization-sensitive Fourier domain optical coherence tomography.
A swept source based polarization-sensitive Fourier domain optical coherence tomography (FDOCT) system was developed that can acquire the Stokes vectors, polarization diversity intensity and birefringence images in biological tissue by reconstruction of both the amplitude and phase terms of the interference signal. The Stokes vectors of the reflected and backscattered light from the sample were...
متن کاملMicrocirculation imaging based on full-range high-speed spectral domain correlation mapping optical coherence tomography.
Microcirculation imaging is a key parameter for studying the pathophysiological processes of various disease conditions, in both clinical and fundamental research. A full-range spectral-domain correlation mapping optical coherence tomography (cm-OCT) method to obtain a complex-conjugate-free, full-range depth-resolved microcirculation map is presented. The proposed system is based on a high-spe...
متن کاملSingle-step method for fiber-optic probe-based full-range spectral domain optical coherence tomography.
We propose a single-step method appropriated for a fiber-optic probe-based full-range spectral domain optical coherence tomography (OCT). The fiber-optic probe was scanned over a sample with a magnetically driven actuator. In the reference arm, a phase shift of π/2 was applied during two neighbor axial scanning, from which the complex spectral interferogram was directly reconstructed. Since the...
متن کاملFull anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.
We demonstrate an extended-imaging-range anterior-segment optical coherence tomography (eAS-OCT) system for the biometric assessment of full AS in human eye. This newly developed eAS-OCT operating at 1340-nm wavelength band is simultaneously capable of an imaging speed of 120 kHz A-line scan rate, an axial resolution of 7.2 μm, and an extended imaging range of up to 16 mm in air. Imaging result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2007
ISSN: 1094-4087
DOI: 10.1364/oe.15.013375