Full-scale Measurements of Wind Loads on High-rise Buildings

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Response of High-Rise Buildings to Stochastic Wind Loads

This paper presents results of a recent study addressing issues concerning the dynamic response of high-rise buildings. Utilizing a high-frequency base-balance, the alon~w;:~d, acrosswind and torsional components of aerodynamic loads and their statistical corm!ations for a wide range of generic building shapes of different aspect ratios in two approach flow conditions are quantified. A random-v...

متن کامل

Assessment of Wind Load Effects on Low-rise Buildings Using Full-Scale Pressure Measurements

This study discusses the wind loads and their effects on Wind Engineering Research Field Laboratory (WERFL) building at Texas Tech University based on full-scale synchronous pressure measurements. The wind load effects on different frames are calculated and the results are compared to those determined based on the wind loads specified in ASCE7-05. Finally, the challenges faced in the modeling o...

متن کامل

Wind pressure measurements on full scale flat roofs

A flat roof surface is known to be subjected to unusually high suction associated with a pair of vortices created under diagonally skewed wind. Prediction of the wind load and its influence on the roof system is an important engineering topic but wind tunnel testing of this situation is not easy with a scaled model. Considering the physics of wind flow for the most critical case, a possibility ...

متن کامل

Evaluation of Equivalent Static Wind Loads on Buildings

Wind loads on buildings can be quantified through synchronous measurements of pressure over building model surfaces or by high frequency force balance (HFFB) measurements. Although this loading information can be directly utilized for building design applications, current design practice often requires the transformation of dynamic wind loading to the equivalent static wind loads (ESWLs). This ...

متن کامل

Equivalent Static Wind Loads on Buildings: New Model

In current design practice, spatiotemporally varying wind loads on buildings are modeled as equivalent static wind loads. This loading description serves as pivotal information for estimating response under the combined action of wind and other loads. This paper presents a framework for evaluating the equivalent static wind load for any given peak response of buildings with uncoupled responses ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Wind Engineers, JAWE

سال: 1996

ISSN: 1883-8413,0912-1935

DOI: 10.5359/jawe.1996.35