Functional outcome of proximal third tibial fractures with intramedullary tibial locking nail and poller screws
نویسندگان
چکیده
منابع مشابه
Intramedullary nailing supplemented with Poller screws for proximal tibial fractures.
PURPOSE To evaluate outcome of intramedullary nailing supplemented with Poller screws for proximal tibial fractures using small diameter nails. METHODS 50 men and 20 women (75 fractures) aged 18 to 65 (mean, 33) years underwent intramedullary nailing supplemented with Poller screws for acutely displaced fractures (n=60) or for delayed union (n=10) or mal-union (n=5) of the proximal metadiaphy...
متن کاملFatigue strength of common tibial intramedullary nail distal locking screws
BACKGROUND Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8-10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery....
متن کاملUnreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third tibial fractures.
PURPOSE To assess the outcome of unreamed intramedullary nailing through the lateralised entry point using oblique proximal and biplanar distal interlocking screws. METHODS 15 men and 3 women aged 25 to 58 (mean, 37) years underwent unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third metaphyseal tibial fractures. The entry point was...
متن کاملBiomechanical stability of intramedullary nailed high proximal third tibial fractures with cement augmented proximal screws.
OBJECTIVE Intramedullary nailing of nonarticular proximal tibia fractures can be affected by bone density resulting in loss of stability, fixation, and malalignment in osteopenic bone. This study was designed to quantify the biomechanical effects of augmenting proximal screws with cement in intramedullary nailing of high proximal third tibial fractures. DESIGN In vitro biomechanical study usi...
متن کاملDistal Locking Screws for Intramedullary Nailing of Tibial Fractures.
Recently introduced tibial intramedullary nails allow a number of distal screws to be used to reduce the incidence of malalignment and loss of fixation of distal metaphyseal fractures. However, the number of screws and the type of screw configuration to be used remains obscure. This biomechanical study was performed to address this question. Thirty-six Expert tibial nails (Synthes, Oberdorf, Sw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Orthopaedics Sciences
سال: 2020
ISSN: 2395-1958
DOI: 10.22271/ortho.2020.v6.i1g.1892