Fundamental study of capacitance coupled electromagnetic flowmeter.
نویسندگان
چکیده
منابع مشابه
An electromagnetic catheter-flowmeter.
An electromagnetic flowmeter incorporated into a catheter is described. The catheter is introduced into the aorta via the femoral artery. The flow sensor is located some distance below the catheter tip and is sensitive to flow at right angles to the catheter. A crater-like elevation at one end of the transducer lumen permits funnel-like connection of the transducer to the ostium of an aortic br...
متن کاملA Transient Electromagnetic Flowmeter and Calibration Facility
Flowmeter and Calibration Facility P.J. Lefebvre Naval Underwater Systems Center, Newport, R.1. An electromagnetic flowmeter was developed to measure transient flows at a data rate of 60 Hz. The approach taken was to develop suitable electronics to replace the electronics ofa commercially available electromagnetic flowmeter normally used W. W. Durgin for steady-state operation. Use of the comme...
متن کاملEffect of hematocrit value upon electromagnetic flowmeter sensitivity.
An electromagnetic flowmeter system that has an accuracy of 0.1% and is insensitive to fluid conductivity was used to study the sensitivity to steady flow of a 6-mm cannular transducer. All measurements were carried out at 37°C. Sensitivity decreased with increasing hematocrit value whether flow was laminar or otherwise. With laminar flow and a given hematocrit value, the sensitivity also decre...
متن کاملThe influence of wellbore inflow on electromagnetic borehole flowmeter measurements.
This paper describes a combined field, laboratory, and numerical study of electromagnetic borehole flowmeter measurements acquired without the use of a packer or skirt to block bypass flow around the flowmeter. The most significant finding is that inflow through the wellbore screen changes the ratio of flow through the flowmeter to wellbore flow. Experiments reveal up to a factor of two differe...
متن کاملA study of Duroziez's murmur of aortic insufficiency in man utilizing an electromagnetic flowmeter.
a large amount of retrograde flow in the femoral artery. Those subjects without significant aortic insufficiency and no Duroziez's murmur had little or no backflow. When only a moderate amount of aortic insufficiency was present, the correlation was less satisfactory. In some subjects who had femoral backflow, a second recording was made from the femoral artery after the aortic valve had been r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Fundamentals and Materials
سال: 1987
ISSN: 0385-4205,1347-5533
DOI: 10.1541/ieejfms1972.107.505