Gas Proportional Scintillation Counter with Xenon and Xenon Mixtures
نویسندگان
چکیده
منابع مشابه
Liquid mixtures of xenon with fluorinated species: xenon + sulfur hexafluoride.
The vapor-liquid equilibrium of binary mixtures of xenon + SF6 has been measured at nine temperatures from 235.34 to 295.79 K and pressures up to 6.5 MPa. The mixture critical line is found to be continuous between the critical points of the pure components, and hence, the system can be classified as type I phase behavior in the scheme of van Konynenburg and Scott. The excess Gibbs free energie...
متن کاملThe gas proportional scintillation counter / microstrip gas chamber hybrid detector
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...
متن کاملXenon–Neon Gas Proportional-Scintillation Counters for X-Rays Below 2 keV: A Monte Carlo Simulation Study
The energy spectra of X-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters, exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this paper, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe–Ne mixt...
متن کاملThe Energy Resolution of Xenon-Neon filled Gas Proportional-Scintillation Counters for X-Rays Below 2 keV
The energy spectra of x-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters (GPSC), exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this work, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe-N...
متن کاملDetection of Liquid Xenon Scintillation Light with a Silicon Photomultiplier
We have studied the feasibility of a silicon photomultiplier (SiPM) to detect liquid xenon (LXe) scintillation light. The SiPM was operated inside a small volume of pure LXe, at -95C, irradiated with an internal Am α source. The gain of the SiPM at this temperature was estimated to be 1.8 × 10 with bias voltage at 52 V. Based on the geometry of the setup, the quantum efficiency of the SiPM was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1968
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1968.4324919