Pll for Single Phase Grid Connected Inverters
In grid connected applications the synchronization of output signals of the converters to be connected with grid parameters frequency and phase is of great importance. Different methods based on Fourier transforms, zero-crossing detection, Kalman filters, phase-locked loops (PLL) and others are used for this synchronization. This paper presents a new PLL for synchronization of the output curren...
متن کاملReview on Single-phase PV Inverters for Grid-connected Applications
In this paper, a review of PV inverters is reported based on converter characteristics as the number of energy processing stages, the presence of a transformer (high-frequency or 50Hz transformer), and the adopted configuration of the PV field. In particular, the considered solutions have been evaluated depending on efficiency, input current ripple and life-time of the capacitors coupling with ...
متن کاملAn Adaptive Hystersis Controller for Single-Phase Grid- Connected PV Central Inverters
An adaptive hysteresis current controller for single-phase single-stage photovoltaic central inverters is presented. The designed controller is able to eliminate harmonic distortion and to control switching frequency and to inject the current into power grid with good power quality. The simulation model of the system is developed in SIMULINK/MATLAB environment. The controller is found effective...
متن کاملDesign of a Digital Voltage Controller in Single-Phase Grid-Connected Renewable Converters
Power decoupling of pulsating grid side power from constant source side power is one of the paramount issues in single phase-phase grid-connected renewable systems. The principal aim of such systems is the decrease of the capacitance of the decoupled capacitor. However, this causes some problems such as an increase in the total harmonic distortion (THD) of injected current to the grid and bus v...
متن کاملOptimization of the Lyapunov Based Nonlinear Controller Parameters in a Single-Phase Grid-Connected Inverter
In this paper, optimization of the backstepping controller parameters in a grid-connected single-phase inverter is studied using Imperialist competitive algorithm (ICA), Genetic Algorithm (GA) and Particle swarm optimization (PSO) algorithm. The controller is developed for the system based on state-space averaged model. By selection of a suitable Lyapunov function, stability of the proposed con...