Generalized iNverse imaging (GIN): Ultrafast fMRI with physiological noise correction

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrafast inverse imaging techniques for fMRI

Inverse imaging (InI) supercharges the sampling rate of traditional functional MRI 10-100 fold at a cost of a moderate reduction in spatial resolution. The technique is inspired by similarities between multi-sensor magnetoencephalography (MEG) and highly parallel radio-frequency (RF) MRI detector arrays. Using presently available 32-channel head coils at 3T, InI can be sampled at 10 Hz and prov...

متن کامل

Automatic Physiological Waveform Processing for fMRI Noise Correction and Analysis

Functional MRI resting state and connectivity studies of brain focus on neural fluctuations at low frequencies which share power with physiological fluctuations originating from lung and heart. Due to the lack of automated software to process physiological signals collected at high magnetic fields, a gap exists in the processing pathway between the acquisition of physiological data and its use ...

متن کامل

Image based physiological noise correction for perfusion-based fMRI

K. Restom, Y. Behzadi, K. Uludag, T. T. Liu Center for Functional MRI, University of California, San Diego, La Jolla, CA, United States Introduction Physiological fluctuations are often a dominant source of noise in fMRI experiments, especially at higher field strengths. A number of methods have been developed for the reduction of physiological noise in fMRI experiments. These include image bas...

متن کامل

Integration of motion correction and physiological noise regression in fMRI

Physiological fluctuations resulting from the heart beat and respiration are a dominant source of noise in fMRI, particularly at high field strengths. Commonly used physiological noise correction techniques, such as RETROspective Image CORrection (RETROICOR), rely critically on the timing of the image acquisition relative to the heart beat, but do not account for the effects of subject motion. ...

متن کامل

Physiological noise reduction using volumetric functional magnetic resonance inverse imaging.

Physiological noise arising from a variety of sources can significantly degrade the detection of task-related activity in BOLD-contrast fMRI experiments. If whole head spatial coverage is desired, effective suppression of oscillatory physiological noise from cardiac and respiratory fluctuations is quite difficult without external monitoring, since traditional EPI acquisition methods cannot samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2012

ISSN: 0740-3194

DOI: 10.1002/mrm.24528