Generation of 1.5 MW–140 GHz Pulses With the Modular Pre-Prototype Gyrotron for W7-X

نویسندگان

چکیده

In anticipation of an Electron Cyclotron Resonance Heating system upgrade for the stellarator Wendelstein 7-X, a 1.5 MW - 140 GHz continuous-wave gyrotron is under development. order to provide first experimental verification scientific RF and electron beam optics design with ms pulses, Karlsruhe Intitule Technology has developed short-pulse pre-prototype gyrotron. this work, we present details regarding construction as well measurements from campaign delivering up 1.6 in short pulses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amplification of picosecond pulses in a 140-GHz gyrotron-traveling wave tube.

An experimental study of picosecond pulse amplification in a gyrotron-traveling wave tube (gyro-TWT) has been carried out. The gyro-TWT operates with 30 dB of small signal gain near 140 GHz in the HE₀₆ mode of a confocal waveguide. Picosecond pulses show broadening and transit time delay due to two distinct effects: the frequency dependence of the group velocity near cutoff and gain narrowing b...

متن کامل

A 250 GHz gyrotron with a 3 GHz tuning bandwidth for dynamic nuclear polarization.

We describe the design and implementation of a novel tunable 250 GHz gyrotron oscillator with >10 W output power over most of a 3 GHz band and >35 W peak power. The tuning bandwidth and power are sufficient to generate a >1 MHz nutation frequency across the entire nitroxide EPR lineshape for cross effect DNP, as well as to excite solid effect transitions utilizing other radicals, without the ne...

متن کامل

A novel wideband 140 GHz gyrotron amplifier

The theory, design and experimental results of a wideband 140 GHz, 1 kW pulsed gyro-traveling wave amplifier are presented. The gyro-TWA operates in the HE(0,6) mode of a novel cylindrical confocal waveguide using a gyrating electron beam. The electromagnetic theory, interaction theory, design processes and experimental procedures have been described in detail. The experiment has produced over ...

متن کامل

Tomography by the maximum entropy method for the W7-AS and W7-X multichannel bolometer systems

Amaximum entropy approach has been applied to the tomographic inversion of the line integrated measurements of radiation power ux by a multichannel bolometer system. This method was applied to a H-mode discharge in the W7-AS stellarator, with increasing radiation from the plasma core after the transition being observed. Also a neutral beam injection discharge was investigated, and the time evol...

متن کامل

Database Structures and Interfaces for W7-X

The W7-X Experiment of the IPP, under construction in Greifswald Germany, is designed to operate in a quasi-steady-state scenario. The database structures and interfaces used for discharge description and execution have to reflect this continuous mode of operation. In close collaboration between the control group of W7-X and the data acquisition group a combined design of the data structures us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Electron Device Letters

سال: 2021

ISSN: ['1558-0563', '0741-3106']

DOI: https://doi.org/10.1109/led.2021.3073221